RI-130 Reader Interface Installation & User's Guide
Go Relay
Go Time
(Seconds)
Position 1
Position 2
Position 3
2
Off
Off
Off
4
Off
Off
On
6
Off
On
Off
8
On
Off
Off
12
On
Off
On
14
On
On
Off
16
On
On
On
Shunt Relay
Shunt Time
(Seconds)
Position 4
Position 5
Position 6
6
Off
Off
Off
12
Off
Off
On
18
Off
On
Off
24
Off
On
On
30
On
Off
Off
36
On
Off
On
42
On
On
Off
48
On
On
On
S2 Codes For Degraded Mode
Switch pack S2 controls how the reader reacts in Degraded Mode. When the RI-
130 looses communication to the Host IC-1600 (or CE-1600), after fifteen
seconds the RI-130 goes into “Degraded Mode.”
When a card is presented to the card reader, the RI-130 will compare the system
code encoded on the card with the system code configured on “S2” of the RI-130.
If the system codes match, the RI-130 will energize the Go and Shunt Relays. In
Degraded-mode the RI-130 will store up to 15,000 transactions (only Card reads).
If that number is exceeded then the first transactions will be over written by the
new transactions. Upon restoration of communications, all stored transactions are
uploaded to the host IC-1600. The following table provides the appropriate
settings for system codes 0 to 255.