background image

4

Function introduction for combination buttons

1. Enery-Saving Function

Under cooling mode, Press "TEMP" and "CLOCK" buttons simultaneously to start up or turn off energy-saving function. When
energy-saving function is started up, "SE" will be shown on remote controller, and air conditioner will adjust the set tempera-
ture automatically according to ex-factory setting to reach to the best energy-saving effect. Press "TEMP" and "CLOCK"
buttons simulataneously again to exit energy-saving function will cancel sleep function.

Note:

Under energy-saving function, fan speed is defaulted at auto speed and it can't be adjusted.

Under energy-saving function, set temperature can be adjusted. Press "TURBO" button and the remote controller won't

send signal.

Sleep function and energy-saving function can't operate at the same time. If energy-saving function has been set under 

cooling mode, press sleep button will cancel energy-saving function. If sleep function has been set under ooling mode, start
up the energy-saving function will cancel sleep function.

2. 8C Heating Function

Under heating mode, press "TEMP" and "CLOCK" buttons simultaneously to start up or turn off 8C heating function. When
this function is stared up, "      " and "8C" will be shown on remote controller, and the air conditioner keep the heating status at
8C. Press "TEMP" and "CLOCK" buttons simultaneously again to exit 8C heating function.

Note:

Under 8C heating function, fan speed is defaulted at auto speed and it can't be adjusted

Under 8C heating function, set temperature can be adjusted. Press "TURBO" button and the remote controller won't send

signal.

 Sleep function and 8C heating function can't oerate at the same time. If 8C heating function has been set under cooling

mode, press sleep button will cancel 8C heating function. If sleep function has been under cooling mode, start up the *C
heating function will cancel sleep function.

Uder F temperature display, the remote controller will display 46F heating.

3. Child Lock Function

Press "

" or "

" simultaneously to turn on or turn off child lock function. When child lock function is on, "      " icon is dis-

played on remote controller. If you operate the remote controller, the "      " incon will blink three times without sending signal
to the unit.

4. Temperature Display Switchover Function

Under OFF status, press "

" and "MODE" buttons simultaneously to switch temperature display between C and F.

Operation Guide

1. After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner. 
2. Press "MODE" button to select your required mode. AUTO, COOL, DRY, FAN, HEAT.
3. Press "

" or "

" button to set your required temperature (Temperature can't be adjusted under auto mode.)

4. Press "FAN" button to set your required fan speed: auto, low, medium, and high speed
5. Press "SWING" button to select fan blowing angle.

Note:

During operation, point the remote control signal sender at the receiving window on indoor unit.

 The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles

between them.

 SIgnal may be interfered easily in the room where there is fluorescent lamp or wireless telephone; remote controller should

be close to indoor unit during operation.

Replace new batteries of the same model when replacement is required

 When you don't use remote controller for a long time, please take out the batteries

If the display on remote controller is fuzzy or there's no display, please replace batteries

Replacement of batteries in remote controller

1. Press the back side of remote controller marked with "       ", as shown in the 
fig, and then push out the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of "+"
polar and "-" polar are correct. 
3. Reinstall the cover of battery box.

Summary of Contents for AWH30LB-D3DNA3D/I

Page 1: ...C Pro S Series 30 36K User Manual Models AWH30LB D3DNA3D I AWH30LB D3DNA3G O AWH30QF D3DNB4K I AWH30QF D3DNB2K O AWH36LB D3DNA3D I AWH36LB D3DNA3G O AWH36QF D3DNB4O I AWH36QF D3DNB2O O Refrigerant R410A ...

Page 2: ......

Page 3: ...ssing the button on the remote controller the signal icon on the display of the remote controller will bilnk once and the air conditioner will give out a de sound which means the signal has been sent to the air conditioner Under the off status set the temperature and clock icon will be displayed on the display of the remote controller if timer on timer off and light functions are set the correspon...

Page 4: ...button can adjust fan blowing angle After Selecting cool mode air conditioner will operate under cool mode Cool indicator on indoor unit is ON Press or button to adjust the temperature Press FAN button to adjust fan speed Press SWING button to adjust fan blowing angle When selecting dry mode the air conditioner operates at low speed under dry mode Dry indicator on indoor unit is ON Under dry mode ...

Page 5: ... status Operation for TIMER ON TIMER OFF is the same 12 TIMER ON TIMER OFF Button TIMER ON button TIMER ON button can set the time for timer on After pressing this button icon disappears and the word on on re mote controller blinks Press or button to adjustTIMER ON setting After each pressing of or button TIMER ON setting will increase or decrease 1 min Hold or button 2s later the time will change...

Page 6: ...ep function has been under cooling mode start up the C heating function will cancel sleep function Uder F temperature display the remote controller will display 46F heating 3 Child Lock Function Press or simultaneously to turn on or turn off child lock function When child lock function is on icon is dis played on remote controller If you operate the remote controller the incon will blink three tim...

Page 7: ...1 7HFKQLFDO QIRUPDWLRQ Service Manual 6 2 Brief Description of Modes and Functions 1 emperature Parameters Indoor preset temperature preset Indoor am ient temperature am 2 Basic Functions Once energi ed in no case should the compressor e restarted within less than 3 minutes In the situation that memory function is a aila le for the first energi ation if the compressor is at stop efore de energi at...

Page 8: ...ection Protection is the same as that under the cooling mode 3 Heating Mode Working conditions and process of heating If Tamb Tpreset 3 6 the unit enters heating mode in which case the four way valve the compressor and the outdoor fan will operate simultaneously and the indoor fan will run at preset speed in the condition of preset cold air prevention If T amb Tpreset 9 the compressor will stop th...

Page 9: ...y rise is not allowed ifTtube 136 F the compressor will run at reduced frequency ifTtube 144 F the compressor will stop and the indoor fan will run at preset speed Heating overload ifTtube 126F the unit will return to its original operation state ifTtube 131 F frequency rise is not allowed ifTtube 136 F the compressor will run at reduced frequency ifTtube 144 F the compressor will stop and the ind...

Page 10: ...cted to the open circuited or short circuited for successive 30 seconds Outdoor tube temperature The sensor is detected to the open circuited or short circuited for successive 30 seconds and no detection is performed within 10 minutes after defrost begins Exhaust After the compressor has operated for 3 minutes the sensor is detected to the open circuited or short circuited for successive 30 sec Ov...

Page 11: ...s may cause an electric shock During cleaning be sure to use a stable and safe standing platform FRONT PANEL CLEANING Wash the front panel using warm water and mild detergent with a soft cloth or soft brush NOTE Do not use bleach abrasives or water above 110 F 45 C as it may cause discoloration or damage to the surface of the unit 1 Open Front Panel Firmly grasp both sides of the front panel and p...

Page 12: ...It is normal for the system to emit a slight fog or water vapor when cooling extremely humid warm air Solution The fog or water vapor will disappear as the system cools and dehumidifies the room space Cause It is normal for the system to make slight cracking sounds from parts expanding and contracting during system starts and stops Solution The noises will discontinue as temperature equalizes afte...

Page 13: ...ied service professional for assistance In the meantime use the Aux Button to operate the system Cause There are a number of system functions that will prevent air flow Solution Check for the following In heating mode the indoor fan may not start for three minutes if the room temperature is very low This is to prevent blowing cold air In heat mode if the outdoor temperature is low and humidity is ...

Page 14: ... the room Furniture that obstructs airflow means you could be heating and cooling the back of a chair instead of the actual living space Remove or rearrange obstacles blocking airflow 6 Try 75 degrees 75 F is a good point for an air conditioner to run at its optimal performance level Even a 5 degree change in temperature can make your unit use up to 40 more energy 7 Lighting Turning lights off can...

Reviews: