background image

2

1. On/Off Button

Press this button can turn on or turn off the air conditioner. After turning on the air conditioner, operation
 indicator “        “ on indoor unit’s diplay is ON (green indicator. The colour is different for different models), and indoor unit will 
give out a sound. 

2. Mode Button

Press this button to select your required operation mode. 

3. FAN Button

Pressing this button can set fan speed circularly as: auto (auto), Low (      ), medium (      ), high (        ).

4. SWING Button

Press this button will select up or down swing angles. Fan blow angle can be selected circularly as seen below.

5. TURBO Button

Under COOL or HEAT mode, press this button to turn to quick COOL or quick HEAT mode. "         " icon is displayed on remote 
controller. Press this button again to exit turbo function and "        " icon will dissapear.

6.

/

 Buttons

Press "

" or "

" button once increase or decrease set temperature 1C (33.8F). Holding "

" or "

" button, 2s later, set

temperature on remote controller will change quickly. On releasing button after setting is finished, temperature indicator on
indoor unit will change accordingly. (Temperature can't be adjusted under auto mode)

 When setting TIMER ON, TIMER OFF or CLOCK, press "

or "▼" button to adjust time. (Refer to CLOCK, TIMER ON,

TIMER OFF buttons) When setting TIMER ON, TIMER OFF or CLOCK, press "▲" or "▼" button to adjust time. (Refer to

CLOCK, TIMER ON, TIMER OFF buttons)

Caution:

Under Auto speed, air conditioner will select proper fan speed automatically according to ex-factory setting.

Fan Speed under dry mode is low speed.

 When selecting auto mode, air conditioner will operate automatically according to ex-factory setting. Set temperature can’t

be adjusted and will not be displayed as well. Press “FAN” button can adjust fan speed. Press “SWING” button can adjust fan
blowing angle. 

After Selecting cool mode, air conditioner will operate under cool mode. Cool indicator “       “ on indoor unit is ON. Press 

“ or “

“ button to adjust the temperature. Press “FAN” button to adjust fan speed. Press “SWING” button to adjust fan 

blowing angle

When selecting dry mode, the air conditioner operates at low speed under dry mode. Dry indicator “     “ on indoor unit is

ON. Under dry mode, fan speed can’t be adjusted. Press “SWING” button to adjust fan blowing angle.

 When selecting fan mode, the air conditioner will only blow fan, no cooling and no heating, All indicators are OFF. Press

“FAN” button to adjust fan speed. Press “SWING” button to adjust fan blowing angle.

 When selecting heating mode, the air conditioner operates under heat mode. Heat indicator “      “ on indoor unit is ON. 

Press “

“ or “

“ button to adjust set temperature. Press “FAN” button to adjust fan speed. Press “SWING” button to adjust

fan blowing angle. (Cooling only unit won’t receive heating mode signal. If setting heat mode with remote controller, press
ON/OFF button can’t start up the unit).

Note:

For preventing cold air, after starting up heating mode, indoor unit will delay 1-5 minutes to blow air (delay time is depen-

dant on indoor ambiet temperature).

 Set temperature range from remote controller. 16~30C (60.8~86F); Fan speed: auto, low, medium, high speed.

 When selecting "     ", air conditioner is blowing fan automatically. Horizontal louver will automatically swing up & down at maximum angle.

 When selecting "

", air conditioner is blowingfan at fixed positions. Horizontal louver will stop at the fixed position.

 When selecting "

", air conditioner is blowing fan at fixed angles. Horizontal louver will send air at the fixed angle.

Hold "       " button above 2s to set your required swing angle. When reaching your required angle, release the button.

Note:

 "

" may not be available. When air conditioner receives this signal, the air conditioner will blow automatically.

Summary of Contents for AWH30LB-D3DNA3D/I

Page 1: ...C Pro S Series 30 36K User Manual Models AWH30LB D3DNA3D I AWH30LB D3DNA3G O AWH30QF D3DNB4K I AWH30QF D3DNB2K O AWH36LB D3DNA3D I AWH36LB D3DNA3G O AWH36QF D3DNB4O I AWH36QF D3DNB2O O Refrigerant R410A ...

Page 2: ......

Page 3: ...ssing the button on the remote controller the signal icon on the display of the remote controller will bilnk once and the air conditioner will give out a de sound which means the signal has been sent to the air conditioner Under the off status set the temperature and clock icon will be displayed on the display of the remote controller if timer on timer off and light functions are set the correspon...

Page 4: ...button can adjust fan blowing angle After Selecting cool mode air conditioner will operate under cool mode Cool indicator on indoor unit is ON Press or button to adjust the temperature Press FAN button to adjust fan speed Press SWING button to adjust fan blowing angle When selecting dry mode the air conditioner operates at low speed under dry mode Dry indicator on indoor unit is ON Under dry mode ...

Page 5: ... status Operation for TIMER ON TIMER OFF is the same 12 TIMER ON TIMER OFF Button TIMER ON button TIMER ON button can set the time for timer on After pressing this button icon disappears and the word on on re mote controller blinks Press or button to adjustTIMER ON setting After each pressing of or button TIMER ON setting will increase or decrease 1 min Hold or button 2s later the time will change...

Page 6: ...ep function has been under cooling mode start up the C heating function will cancel sleep function Uder F temperature display the remote controller will display 46F heating 3 Child Lock Function Press or simultaneously to turn on or turn off child lock function When child lock function is on icon is dis played on remote controller If you operate the remote controller the incon will blink three tim...

Page 7: ...1 7HFKQLFDO QIRUPDWLRQ Service Manual 6 2 Brief Description of Modes and Functions 1 emperature Parameters Indoor preset temperature preset Indoor am ient temperature am 2 Basic Functions Once energi ed in no case should the compressor e restarted within less than 3 minutes In the situation that memory function is a aila le for the first energi ation if the compressor is at stop efore de energi at...

Page 8: ...ection Protection is the same as that under the cooling mode 3 Heating Mode Working conditions and process of heating If Tamb Tpreset 3 6 the unit enters heating mode in which case the four way valve the compressor and the outdoor fan will operate simultaneously and the indoor fan will run at preset speed in the condition of preset cold air prevention If T amb Tpreset 9 the compressor will stop th...

Page 9: ...y rise is not allowed ifTtube 136 F the compressor will run at reduced frequency ifTtube 144 F the compressor will stop and the indoor fan will run at preset speed Heating overload ifTtube 126F the unit will return to its original operation state ifTtube 131 F frequency rise is not allowed ifTtube 136 F the compressor will run at reduced frequency ifTtube 144 F the compressor will stop and the ind...

Page 10: ...cted to the open circuited or short circuited for successive 30 seconds Outdoor tube temperature The sensor is detected to the open circuited or short circuited for successive 30 seconds and no detection is performed within 10 minutes after defrost begins Exhaust After the compressor has operated for 3 minutes the sensor is detected to the open circuited or short circuited for successive 30 sec Ov...

Page 11: ...s may cause an electric shock During cleaning be sure to use a stable and safe standing platform FRONT PANEL CLEANING Wash the front panel using warm water and mild detergent with a soft cloth or soft brush NOTE Do not use bleach abrasives or water above 110 F 45 C as it may cause discoloration or damage to the surface of the unit 1 Open Front Panel Firmly grasp both sides of the front panel and p...

Page 12: ...It is normal for the system to emit a slight fog or water vapor when cooling extremely humid warm air Solution The fog or water vapor will disappear as the system cools and dehumidifies the room space Cause It is normal for the system to make slight cracking sounds from parts expanding and contracting during system starts and stops Solution The noises will discontinue as temperature equalizes afte...

Page 13: ...ied service professional for assistance In the meantime use the Aux Button to operate the system Cause There are a number of system functions that will prevent air flow Solution Check for the following In heating mode the indoor fan may not start for three minutes if the room temperature is very low This is to prevent blowing cold air In heat mode if the outdoor temperature is low and humidity is ...

Page 14: ... the room Furniture that obstructs airflow means you could be heating and cooling the back of a chair instead of the actual living space Remove or rearrange obstacles blocking airflow 6 Try 75 degrees 75 F is a good point for an air conditioner to run at its optimal performance level Even a 5 degree change in temperature can make your unit use up to 40 more energy 7 Lighting Turning lights off can...

Reviews: