Page 15
AN120076.000_EN
Para-
meter
Range
Unit
Designation
Remarks
P 5.0
300
ms
Extend measurement time (main lift only)
Code
May only be changed with
the permission of ABUS
P 5.01
20 – 255
Sensitivity to rapid load increase
Code
May only be changed with
the permission of ABUS
P 5.1
h
Display of
theoretical service life
P 5.2
h
Read load population recorder
P 5.3
Acceptance test
P 5.4
12 – 30
Set / change inching counter
May only be changed with
the permission of ABUS
P 5.5
Delete all settings
P 6.1
Display / input Starting value for load population recorder
P 6.2
h
Display
Actual hours of use S
P 6.3
h
Display
Total operating hours Ti
P 6.4
h
Set FEM group
Special ABUS CODE
This parameter is used to
enable the load population
recorder;
The parameter can only be
set by ABUS.
P 6.5
delete load population recorder
Code
CODE only accessible to
inspector.
P 7.0
Password input for level 3
Only for ABUS
P 9.9
Quit parameter level
Quit menu level
11
Description of LIS – SE parameters
0015
Operating hours are displayed on unit.
This display appears if
1. after the hoist has been shut down for about 3 sec.
2. after you have pressed the ”Enter” button briefly
Menu level 1
CodE
Readout of load population re-
corder by customer:
Appears on the display if you press the
Enter
key for
some time, provided that the load population recorder
has been enabled by ABUS.
Menu level 2
Before carrying out any settings on the LIS–
SE, you should read the notes on the para-
meters carefully.
Always remember that incorrect settings may
cause malfunction.
ABUS will assume no liability whatsoever for
any damage to the crane or any consequen-
tial damage resulting from incorrect settings.
On level 2, if no entries are made for 5 minutes, the unit
switches to the operating mode.
All entries made and saved up to that point are maintai-
ned.
Parameter:
P 0.0
Total load capacity of crane or sy-
stem
Adjustment:
This parameter currently has no effect on evaluation. It
is not necessary to enter a value.