LED CHARGE STATUS INDICATOR
The status display is equipped with four indicator lights:
ERROR MESSAGE
The charging cable has several monitoring functions, which are indicated by the signal LEDs.
POWER
CHARGE
SIGNAL 1
SIGNAL 2
Connected to power and ready for use
Charging process
Error message
Error message
POWER
:
CHARGE
:
SIGNAL 1
:
SIGNAL 2
:
Deutsch .
English
PO
W
ER
CH
AR
GE
SI
GN
AL
1
SI
GN
AL
2
Description
Declaration
Initialization
After mains contact, the control box carries out an initialisation with self-test.
Connected
Sleep mode.
Charging
Battery is charging.
Charging completed
Battery is full charged.
Failed self-test
Internal fault in the control box. Send the charging cable to the manufacturer for
inspection.
Communication error
The control box cannot establish communication with the EV. Check the connectors
for correct seating and for dirt in the de-energised state. If the fault cannot be
rectified, send the charging cable to the manufacturer for inspection.
Over / low voltage
The supply voltage is outside the tolerance range. Please check the mains voltage.
PE error
The control box detects a fault in the PE line. Please check your installation.
Over current
The charging current is above the maximum value. Stop charging and check the
compatibility of the charging cable.
Leakage current
The control box detects a fault current. Abort the charging process, disconnect the
charging cable from EV and check your wiring / vehicle. Visit a specialist workshop.
Charging overheated
The control box is overheated. This can be caused, for example, by direct sunlight
during the charging process. The charging process is interrupted. After cooling
down, the charging process starts automatically.
= ON
= FLASH
=
OFF