EN
25
SAFETY
ALWAYS INSTALL SAFETY ACCESSORIES IN CONFORMITY WITH THE ESSENTIAL
REQUIREMENTS OF THE NATIONAL STANDARD OF THE COUNTRY WHERE THE EQUIPMENT
IS INSTALLED; AN EXTERNAL FIRE MAY PRODUCE AN EXCESS OF HEAT WHICH MAY CAUSE
THE PRESSURE EQUIPMENT TO EXCEED ITS LIMITS
DO NOT EXPOSE THE PRESSURE EQUIPMENT TO ANY IMPACT THAT MAY CAUSE DAMAGE
DURING OPERATION
DO NOT WELD ANYTHING ONTO THE PRESSURE EQUIPMENT
DO NOT USE THE PRESSURE EQUIPMENT FOR ANYTHING DIFFERENT FROM WHAT
PRESCRIBED
IN CASE OF LEAKAGE, STOP IMMEDIATELY THE OPERATION OF THE PRESSURE EQUIPMENT
DISPOSAL
Evaporator
Nominal thickness: mm
Ev 19xx
Ev 21xx
Ev 27xx
Ev 32xx
Ev 35xx
Ev 40xx
Ev 50xx
Ev 55xx
Ev 67xx
4.5
5
5.2
5.2
6.3
6.3
6.3
6
6
2.2
2.3
2.6
2.8
2.9
3.2
3.6
4.1
4.5
Minimum thickness: mm
ACCEPTABLE MINIMUM THICKNESSES: SHELL
Evaporator
Nominal thickness: mm
Ev 19xx
Ev 21xx
Ev 27xx
Ev 32xx
Ev 35xx
Ev 40xx
Ev 50xx
Ev 55xx
Ev 67xx
12
15
15
20
20
20
22
25
29
6.5
7.2
9.8
11.5
12.5
14.1
17.4
19.1
22.9
Minimum thickness: mm
ACCEPTABLE MINIMUM THICKNESSES: END CAP (U TUBE BUNDLE EVAPS. ONLY)
Evaporator
Nominal thickness: mm
Ø 88.9
Ø 114.3
Ø 139.7
Ø 168.3
Ø 219.1
Ø 273
4
4
4.5
4.5
5
6.3
1.8
1.9
2
2.1
2.3
2.6
Minimum thickness: mm
ACCEPTABLE MINIMUM THICKNESSES: WATER NOZZLES
This pressure equipment contains recyclable materials (carbon steel, copper,
plastics, etc.).
At the end of its useful lifetime get information about the laws in force in your
country regarding recycling.
PROVIDES pressure equipment is supplied with recyclable packaging.
11. Safety - 12. Disposal
ALWAYS INSTALL SAFETY ACCESSORIES IN CONFORMITY WITH THE ESSENTIAL
REQUIREMENTS OF THE NATIONAL STANDARD OF THE COUNTRY WHERE THE
EQUIPMENT IS INSTALLED; AN EXTERNAL FIRE MAY PRODUCE AN EXCESS OF HEAT
WHICH MAY CAUSE THE PRESSURE EQUIPMENT TO EXCEED ITS LIMITS
DO NOT EXPOSE THE PRESSURE EQUIPMENT TO ANY IMPACT THAT MAY CAUSE
DAMAGE DURING OPERATION
DO NOT WELD ANYTHING ON THE BODY OF THE PRESSURE EQUIPMENT
SAFETY
DO NOT USE THE PRESSURE EQUIPMENT FOR
OPERATION
DIFFERENT FROM
WHAT
IS
PRESCRIBED
IN CASE OF LEAKAGE,
IMMEDIATELY
STOP THE
OPERATION
OF THE
EQUIPMENT
Summary of Contents for Provides
Page 1: ...Flooded Heat Exchangers Operating Instructions...
Page 2: ...2 OUR PRODUCTS...
Page 28: ...EN 28 Fig 14 2 VICTAULIC CONNECTION BOLTS GASKET COUPLINGS 14 Appendix APPENDIX...
Page 29: ...EN 29 14 Appendix...
Page 30: ......
Page 31: ......