2 Installation and Operating Instructions

Installation and Operating Instructions

ABS Control panel CP114

GB 0825-A

CP114 is a control panel for connection to a single-phase mains supply 230 V/N/PE.  

m

Max. pre-fusing 16 A. If a residual-current protection device (RCD) is used, a 2-pol. universal-current-

Max. pre-fusing 16 A. If a residual-current protection device (RCD) is used, a 2-pol. universal-current-
sensitive or a super immunized RCD is recommended.

A three-phase pump 3x230 V max. IN=10 A can run on a variable frequency drive (VFD) type Altivar ATV12 
(see part-no.).

Part-no.: 6216 0870 – CP114 up to 1,5 kW; 7,5 A  

(Part-no. VFD 1285 0276)

Part-no.: 6216 0871 – CP114 up to 2,2 kW; 10,0 A 

(Part-no. VFD 1285 0277)

,ISUREOHPVRFFXUZLWKH[LVWLQJ5&'LQVLGHLQVWDOODWLRQLQWHUQDO(0&¿OWHURIWKH9)'FDQEHGLVDEOHG7KLVFDQ

affect the EMC.

CP114 will be controlled by the ABS Pump Controller PC111 (part-no. 1270 0002). Useable PC111 units with the 

XSGDWH¿UPZDUH9HU

0825-0002

Figure 1 Pump controller PC111

7KLVPDQXDOLVDVXSSOHPHQWWRWKHVWDQGDUGPDQXDOVRIWKH3&DQGVLPSOL¿HGPDQXDORIWKH$79$OO

connections must be carried out in accordance to the enclosed wiring diagram.

General Information

Main switch –Q0 interrupted the total control panel.

Fuse – F2 only protects the controller – A1. VFD –A10 remains active.

m

Analogue and digital level-inputs of PC111 are not intrinsically safe. In Ex-applications additional ap-
propriate safeguards are necessary.

Fuse – X1/8 protects circuit of accumulator (option).

Key lockable steel cabinet with separate wall brackets and cable glands.