Installation and Operating Instructions

ABS submersible sewage pump AFP 0831S and 0841S

Legend

1002-00

Model

Pump type/ Item No.

SN

Serial No.

UN

Rated Voltage

P2

Rated Output Power

HP

F.L.Amps

Full Load Amps

Hz

Frequency

Phase

Three/Single Phase

RPM

Speed

min-1

Imp. dia

Impeller diameter

mm

Max.

 

Max submersible depth

Ft

Flow Max. Rated Discharge

GPM

Head Max. Max. Head

Ft

 FM version nameplate

Legend

1003-00

Type

Pump type

Nr./SN

Item No./Serial No.

xx/xxxx Production date (Week/Year)
UN

Rated Voltage

V

IN

Rated Current

A

Frequency

Hz

P1N

Rated Input Power

kW

P2N

Rated Output Power

kW

n

Speed

min-1

Qmax

Max. Flow

m3/h

Hmax

Max. Head

m

Ø Imp.

Impeller diameter

mm

DN

Discharge diameter

mm

SS

Water pressure tight

IP 68

Protection type

Standard version nameplate

Safety

The general and specific Health and Safety requirements are described in detail in the 

Safety Instructions for 

ABS Products

 booklet. If anything is not clear or you have any questions as to safety make certain to contact 

the manufacturer ABS.

Transport

m

  During transport the unit should not be dropped or thrown.

c

  The unit should never be raised or lowered by the power cable.

The unit is fitted with a lifting device to which a chain and shackle may be attached for transport purposes.

m

  Any hoist used must be adequately dimensioned for the weight of the unit.

All relevant safety regulations as well as general good technical practice must be complied with.

Summary of Contents for AFP 0831S

Page 1: ...www absgroup com ABS submersible sewage pump AFP 0831S and 0841S 1007 00 15975144GB 05 2010 GB Installation and Operating Instructions ...

Page 2: ...mps in explosive zones 5 1 2 Technical data 5 1 2 1 Nameplate 5 2 Safety 6 3 Transport 6 4 Setup and installation 7 4 1 Installation example in concrete sump 7 4 3 Electrical connection 8 4 3 1 Wiring diagrams 8 4 3 2 Checking direction of rotation 9 4 3 3 Changing direction of rotation 9 5 Commissioning 10 6 Maintenance 10 6 1 General maintenance hints 10 6 2 Commentary on maintenance of lifting ...

Page 3: ...hermal sensing system connected If ball type float switches are used these must be connected to an intrinsically safe electrical circuit Protection type EX i in accordance with VDE 0165 Dismantling and repair of submersible explosion proof motors may only be carried out by approved personnel in specially approved workshops 1 2 Technical data Maximum noise level 70 dB This may be exceeded in certai...

Page 4: ...3 h Hmax Max Head m Ø Imp Impeller diameter mm DN Discharge diameter mm SS Water pressure tight IP 68 Protection type Standard version nameplate 2 Safety The general and specific Health and Safety requirements are described in detail in the Safety Instructions for ABS Products booklet If anything is not clear or you have any questions as to safety make certain to contact the manufacturer ABS 3 Tra...

Page 5: ...ne 3 Sump cover 4 Sleeve for cable protective duct to the control panel 5 Chain 6 Inflow line 7 Ball type float switch 8 Submersible pump 9 Concrete sump 10 Pedestal 11 Guide tube 12 Discharge line 13 Non return valve 14 Gate valve 15 Power cable to motor Installation example in concrete sump 4 2 Discharge line The discharge line must be installed in compliance with the relevant regulations DIN 19...

Page 6: ...on the control panel must comply with the circuit diagram of the control panel as well as the motor connection diagrams and must be carried out by a qualified person All relevant safety regulations as well as general good technical practice must be complied with ATTENTION For use in the open air the following VDE regulations apply Submersible pumps used outdoors must be fitted with a power cable o...

Page 7: ...rection of rotation is correct if the impeller propeller rotates in a clockwise manner when viewing down from the top of the placed unit 1020 00 ATTENTION The start reaction is anti clockwise Rotor rotation NOTE If a number of pumps are connected to a single control panel then each unit must be individually checked ATTENTION The mains supply to the control panel should have a clockwise rotation If...

Page 8: ...ed function easily Have the hydraulics been vented in the case of dry installed pumps 6 Maintenance c Before commencing any maintenance work the unit should be completely disconnected from the mains by a qualified person and care should be taken that it cannot be inadvertently switched back on m When carrying out any repair or maintenance work the safety regulations covering work in enclosed areas...

Page 9: ...ll Quantity AFP 50 Hz AFP 60 Hz Pump Type Litres Pump Type Litres AFP 0831 S22 4 0 6 AFP 0831 S25 4 0 6 AFP 0841 S13 4 0 6 AFP 0841 S16 4 0 6 AFP 0841 S22 4 0 6 AFP 0841 S25 4 0 6 An oil change is only necessary if a fault occurs m Repair work on explosion proof submersible pumps may only be carried out by approved personnel in approved workshops When carrying out repairs only original spare parts...

Page 10: ...12 Installation and Operating Instructions ABS submersible sewage pump AFP 0831S and 0841S ...

Page 11: ... aux normes ou à d autres documents normatifs ES Objeto de esta declaración están conformes con las siguientes normas u otros documentos normativos PT Aque se refere esta declaracáo está em conformidade com as Normas our outros documentos normativos IT Ai quali questa dichiarazione si riferisce sono conformi alla seguente norma o ad altri documenti normativi NL Waarop deze verklaring betrekking he...

Page 12: ...ABS Production Wexford Ltd Clonard Road Wexford Ireland Tel 353 53 91 63 200 Fax 353 53 91 42335 www absgroup com ...

Reviews: