![background image](http://html1.mh-extra.com/html/abs/abt-frp-04/abt-frp-04_owners-manual_3502201009.webp)
P a g e
| 9
CHECK TEMPERATURE HISTORY
Press [UP] button. The display will show the maximum temperature ever reached since
the last reset.
Press [DOWN] button. The display will show the minimum temperature ever reached
since the last reset.
Press [UP] and [DOWN] button together simultaneously for 4 seconds to clear out the
history. The maximum and minimum record will be erased, and record the next
maximum and minimum temp point.
MENU
Press [MENU] button to enter the user adjustable settings. Press [UP] or [DOWN] to
select which setting you would like to make an adjustment.
CODE
DESCRIPTION
FACTORY DEFAULT
ALU
High temp alarm point
10°C or 50°F (refrigerator)
0°C or °F (freezer)
ALL
Low temp alarm point
0°C or 32°F (refrigerator)
-30°C or °F (freezer)
Ad
Visual & audible alarm delay (minute)
0 (minute)
CF
Celsius & Fahrenheit unit change
°C or °F
dA
Door ajar alarm (minutes)
NO (disable)
Door alarm is for selected
models only.
rD
Remote alarm delay (minute)
20 (minute)
Snd
Mute duration (minute)
120 (minute)
OFF
Temp readout calibration / offset
Current readout