background image

TROUBLE SHOOTING    

 

11

 

Fault Possible 

Cause 

Remedy 

The mixer does not 
stop 

Electrical / mechanical 
malfunction. 

Switch off power at 
main switch.   
Isolate mixer by 
unplugging. 

 

Attach danger tag to 
machine. 

 

Contact authorized 
service agent. 

Bread dough too soft. 

Excessive water used in 
dough (human error). 
 

 

Incorrectly metered / 
measured through water 
meter (equipment error). 

 

Over-mixed dough 

Review recipe and 
adjust dough 
consistency. 

 

Contact authorized 
maintenance. 

 

Review/check 
/adjust mix cycle. 

Final dough temperature 
too hot. 

Water temperature too 
hot. 

 

Dough mixed too long. 

Reduce water 
temperature. 

 

Shorten mix cycle. 

Final dough temperature 
too cold. 

Water temperature too 
cold. 

 

Dough mixed too shot. 

Increase water 
temperature. 

 

Lengthen mix time. 

Dough is difficult to 
remove from the mixing 
bowl. 

   

 

Dough over-mixed. 

 

Refer-dough too 
soft. 

 

Run food grade oil 
between dough and 
bowl at the end of 
mix cycle to stop 
dough sticking. 

Summary of Contents for ABSFBM-120T

Page 1: ...OWNER S MANUAL ABSFBM 120T Spiral Mixer...

Page 2: ...CONTENTS 1 Introduction 2 Installation Commissioning 3 Operation 4 Caution 8 Cleaning Maintenance 9 Trouble Shooting 10 Parts List 12 Wiring Diagram 20...

Page 3: ...rators should carefully read and familiarize themselves with this entire manual before attempting to operate or service this machine Complying with this manual will ensure years of safe and trouble fr...

Page 4: ...es are not designed to support the unit while mixing 3 Connect the correct power supply to the machine as indicated on the machine nameplate Commissioning 1 Start the mixer to check the direction of r...

Page 5: ...button to lessen the time on the timer When the spiral mixer is switched ON timers will show the set time The timer will only be operative when mixer is in AUTO mode The timer will start automaticall...

Page 6: ...the hook is in the fast speed state D Bowl inching light When INCH lamp lights up spiral mixer is in manual inch mode This button is also operative when the safety guard is lifted E On model light Wh...

Page 7: ...on when the safety guard is lifted Complete ingredient should be checked to ensure accuracy in scale Operation Steps 1 Auto operation A Press buttons below timer to set the desired time for reverse bo...

Page 8: ...fast speed to start When the mixer is running at slow speed you can press the button to engage high speed 3 Control Buttons When digital panel is damaged the mixer can be operated by manual switch lo...

Page 9: ...ectrical connections or non insulated cables 7 Periodically check the state of the power cord and the cable clamp on the machine body replace it if necessary by an authorized service provider 8 Discon...

Page 10: ...the dough spiral under the bowl cover inside the mixing bowl and behind the mixing bowl 4 Wipe all surfaces with warm water 5 Apply a detergent sanitizer and leave on all surface 6 Scrub to loosen an...

Page 11: ...tact supervisor service agent The mixer labors under load Belts screech Dough too stiff tight Machine malfunction Review and adjust dough consistency eg Add more liquid Contact supervisor Service agen...

Page 12: ...rror Over mixed dough Review recipe and adjust dough consistency Contact authorized maintenance Review check adjust mix cycle Final dough temperature too hot Water temperature too hot Dough mixed too...

Page 13: ...PARTS LIST 12...

Page 14: ...PARTS LIST 13...

Page 15: ...PARTS LIST 14...

Page 16: ...PARTS LIST 15...

Page 17: ...PARTS LIST 16...

Page 18: ...sting Wheel SM120T016 15PDL7M 925 Belt 7M 925 5pcs SM120T017 15ZCL3209VV Bearing 3209VV SM120T018 15YFL50 70 9 Oil Seal 50 70 9 SM120T019 15ZCL6210 Bearing 6210 SM120T020 14M350 01 Top Bearing Housing...

Page 19: ...15ZCL3211VV Bearing 3211VV SM120T052 14M320 12TT 02 Top Motor Pulley For 50HZ SM120T053 11M270 12TT Adjust Plate for Motor SM120T054 14M330 09 02 Bottom Motor Pulley SM120T055 11M290 06 Adjust Plate f...

Page 20: ...4M410 12TT 02 Transmission Shaft SM120T087 15ZCL6210VV Bearing 6210VV SM120T088 11M430 03 Fixing Piece 10T 30 100 SM120T089 14M420 12TT Bearing Housing SM120T090 11M430 03 Fixing Piece 10T 30 100 SM12...

Page 21: ...WIRING DIAGRAM 20...

Reviews: