21
EN
Technical Data
Assembly / Installation
The product is to be set up or installed at the inten-
ded use site under due consideration of the following
conditions:
• At the location and site all applicable provisions of
law must be clarified and compliance with them
assured.
• The ground and space relations are to be clarified
prior to set-up/installation of the product in order
to assure safe operation for the personnel and the
product long-term. The product must be set-up/
installed so that safe, permanent operation is
assured.
• The product may only be set up and commissioned
by specially trained technicians.
• The product is constructed for rooms that are
protected from the influence of the weather
(industry standard).
• The operation and storage in aggressive or humid
environments or outdoors can lead to corrosion
damages.
Commissioning
The system was fully tested before delivery and set to
the previously specified container size.
NOTE
Ensure that all screws and hoses
are tightened properly (leaks
• Remove all packaging from the system before
commissioning.
• Turn the rotary switch (Figure B/no.5) to
Hold.
• Connect the system to the compressed air supply.
• Open the shut-off valve (Figure F/no.14).
• Check the air pressure at the pressure gauges.
Container
25 kg
up to 25 kg
up to 180 kg
Model
AXFP2-S25-
Light
AXFP3-S25-
Light
AXFP4-S25-
Light
Pressure ratio
25:1
25:1
25:1
Pump delivery volume at the outlet (cm
3
/min)
1‘295
1‘295
1‘295
Connection port (media) AG Figure C/no. 9
G 1/4“
G 1/4“
G 1/4“
Internally threaded connection (compressed air)
Figure C/no. 8
G 1/4“
G 1/4“
G 1/4“
Pump design
Type S
Type S
Type S
Max. container height (mm)
430
680
870
Min/max internal container diameter (mm)
260 - 410
260 - 410
560 - 575
Outlet pressure (media) at a working
pressure of 6 bar
140
140
140
Outlet pressure (media) at a working
pressure of 10 bar
233
233
233
Min. /Max. working pressure (bar)
4/10
4/10
4/10
Max. air consumption (l/min)
217
217
217
Pumping volume per double stroke (cm
3
)
17
17
17
Summary of Contents for AXFP2-Light Series
Page 2: ...2 A E B D F 1 4 F 2 6 7 3 4 5 10 12 13 14 15 10 2 5 9 8 2 C 6 11...
Page 3: ...3 G I H 25 20 18 17 19 21 20 16...
Page 6: ...6...
Page 16: ...16...
Page 26: ...26...
Page 36: ...36...
Page 46: ...46...
Page 56: ...56...
Page 66: ...66...
Page 76: ...76...
Page 86: ...86...
Page 96: ...96...
Page 106: ...106...
Page 107: ...107...