35
0 VDC
24 VDC
Presence impulse
Not in use
Presence detection
Not in use
Not in use
*
4
3
2
1
LED
NC
NO
C
4
3
2
1
LED
NC
NO
C
Blue
Grey
White
Red
Black
Yellow
Green
Red
EL490 Motor lock EL590 Motor lock
CONNECTION EXAMPLES
CONTROL UNIT AND
EXTENSION UNIT EXB-FI
Fire door use
CONTROL UNIT
EXTENSION UNIT EXB-FI
26
27
28
32
31
30
29
TB4
5678
TB2
91
01
11
21
31
4
FS
ON
12345678
Operation: When fire detector reacts, the program selector goes to MANUAL mode and impulse devices wont open the door. Do not connect impulse devices between TB2:5 and TB2:13. Otherwise lock will open when fire detetors are active.
When fire alarm has gone off, the program selector will remain in MANUAL mode. The operator will revert back to normal operatio
n
when voltage is disconnect from fire detectors. For this purpose install switch (*) with opening contact.
Power failure -> door closes Fire alarm -> door closes
NOTE! FS1 = OFF FS4 = ON FS5 = ON