5
EN1154 classification.
TECHNICAL SPECIFICATIONS
·
Mains power supply: 230 VAC (-10 - +10 %), 50 Hz, fuse 10 A
·
Power consumption: max 230 W
·
Auxliary voltage : stabilized 24 VDC, 700 mA
·
Motor Fuse: 6,3 AT
·
Control unit fuse: 250 mAT
·
Class of protection IP20
·
Dimensions: 716 mm x 110 mm x 110 mm (Length, Depth, Height)
·
Weight: 11 kg
·
Operation: -15...+30°C (in dry premises)
·
The automatic swing door operator must not be installed in applications where it is subjected
to water or snow.
·
Maximum recommended door weight/width:
Standard arm: 250 kg / 1600 mm
Sliding arm: 100 kg / 1400 mm
·
Limit switch (DB102): 1A, 48 VDC, NO
Note the maximum door weight in fire doors. Class 6 door closer will
close door 120kg / 1400 mm
.
Mount a door stop to the door open position so that wind will not drive
the door against the wall, resulting in damage
Class
Standard arm
Sliding arm
Closing
torque
Door weight[kg] Door weight[kg]
[Nm]
/ width[mm]
/ width[mm] (0-4°)
1
20 / 750
9
2
40 / 850
13
3
60 / 950
60 / 950
18
4
80 / 1100
80 / 1100
26
5
100 / 1250
37
6
120 / 1400
54