MF3-Laser Front/Rear
6 Commissioning
EN
-
11
6.1 Mounting the drive
1
Position the device on the media plate.
2
Pay attention to the position of the dowel pins in
relation to the holes.
3
Lock the device and the media plate with the
media plate’s quick-release clamps.
4
Turn the lug on the tension lock clockwise by at
least 180°.
5
Before connecting the wire feeder to the wire
guide hose, check whether the proper wire guide
(liner or PA liner) has been inserted in accordance
with the wire diameter and wire type.
6
Insert the control lead, flex supply, and wire guide
hose into the appropriate connectors one after the
other.