BAL.0716.0 • 2022-01-11
EN
-
15
ABIPLAS
®
CUT HF
7 Operation
3
Attach the swirl ring.
4
Attach the selected plasma nozzle.
• The type of plasma nozzle used is primarily determined by the thickness of the material to
be cut and the current intensity.
Tab. 3 Product-specific torch data (EN 60974-7) on page EN
• The following standard values apply:
NOTICE
• Over-tightening can damage the thread.
NOTICE
• Ensure that it is positioned correctly.
• The air holes should always point towards the electrode tip.
Type
Plasma
nozzle
ø
[mm]
Current intensity
[A]
ABIPLAS
®
CUT
71 HF/71 HF MT
Standard
0.9
30
Standard
1.1
30–60
Standard
1.2
50–70
Long
0.9
30
Long
1.1
30–50
Cross slot
0.9
30
Cross slot
1.1
30–60
Long cross slot
0.9
30
ABIPLAS
®
CUT
111 HF/111 HF MT
Standard
1.0
30–50
Standard
1.2
40–70
Standard
1.4
70–90
Standard
1.6
90–110
Long
1.2
50
Long cross slot
1.2
50
Gouging
2.6
Tab. 8
Standard values