TIG cold-wire feeder
6 Putting into operation
BAL.0415.0 • 2018-10-22
EN - 15
Setting the torch triggers
Function F5 can be used to configure rockers T1 and T3
:
6.4.2 2-cycle and 4-cycle interval with wire retraction (infinitely adjustable, continual forwards and
backwards movement)
This interval mode is switched on using function
F7
(ON).
The function
tof
stops the wire feed for the preset period.
The wire feed rate is set using the function
SPE
.
The wire retraction feed rate is set using function
F2
.
The applicable parameter settings can be found in the following table:
Left display
Right display
F5
A
T1 = wire feed
T3 = wire retraction
b
T1 = increases the wire feed rate in standby mode during welding
T3 = reduces the wire feed rate in standby mode during welding
C
T1 = wire feed and increases the wire feed rate in standby mode during welding
T3 = wire retraction and reduces the wire feed rate in standby mode during welding
Tab. 12
Setting the rocker
Function
Description
Explanation of the setting process
F7
Wire retraction mode
Tab. 10 Display indicators for advanced functions on page EN-13
tof
Wire feed interval break
Tab. 9 Display indicators after switching on on page EN-11
SPE
Wire feed rate
Tab. 9 Display indicators after switching on on page EN-11
F2
Wire retraction feed rate
Tab. 10 Display indicators for advanced functions on page EN-13
Tab. 13
Wire retraction settings
Fig. 10
Example of interval functions
Interval
Interval
T2
Motor
Motor
F7=OFF
F7=ON
2T
t1
t2
m/min
m/min
ton
dt
dt
tof
tof
rE
rE
ton