background image

-1-

BUMPER TO BUMPER WARRANTY

BENEFITS OF CADPXS WARRANTY

WARRANTY REGISTRATION

By choosing CADPXS, you will be sure that you have a commercial-
grade dehumidifier that will perform the job it is designed for. 
These are state of the art dehumidifiers that are backed with a 
bumper to bumper warranty. 

A CADPXS bumper-to-bumper warranty covers the entire product 
and  accessories, 

electrical 

parts 

and  components, 

safety 

equipment and instruments.

It does not cover parts of the product that wear and tear with time. 
It does not cover routine maintenance tasks. Parts damaged by 
you, an accident, or improper maintenance are also not covered.

Coverage from dealerships can be more costly due to the fact that 
it  may  be  rolled  into  your  product  payment  plan  and  accrue 
interest. Third-party extended warranty costs will vary depending 
on  the  make  and  model  of  your  product,  your  product  usage 
history, and other factors. 

If you want to avoid unexpected expensive repairs, a bumper-to-
bumper warranty can protect you financially and provide you with 
peace  of  mind  that  you’ll  be  taken  care  of.  product  service 
contracts also usually include added benefits such as technical 
assistance, repairs, and in some cases installation assistance.

CADPXS believes in the quality of its products. This is why it stands 
behind its products and gives a more extended warranty than what 
you  can  get  elsewhere. 

To  CADPXS,  a  longer  warranty  is  an 

important 

aspect  of  our  service. 

This  is  the  reason  why  the 

company fully supports its bumper to bumper warranty. 

The warranty is valid if claimed by an original buyer and if bought 
from CADPXS, authorized reseller or dealer. The company covers 
the cost of the components, the cost of labor required to repair the 
unit.  However, 

the  cost  of  dissembling, 

transportation, 

and 

installing the product will be paid by the client. 

-10-

-2-

WIRING DIAGRAM

 FLOAT SWITCH (LOW)

TRANSFORMER

FUSE

NO

COM

33k

N

N

F

AN -L

N

VALUE

DRAIN

FLOA

T

 - H

POWER
BOARD

RH-OUT

RH-IN

THERMISTOR 
     PROBE

EVAP

RH-IN

RH-OUT

TEMP/RH
SENSOR

FLOA

T

 - L

CONTROL
BOARD

L

N

GRN

PUMP
(24v)

S

R

C

GRN

COMP

COMPRESSOR
CAPACITOR

BLOWER

BLOWER
CAPACITOR

WHT

GRN

BLK

BLK

WHT

RED

RED

BRN

BLU

BRN

BLU

TEMP/RH
SENSOR

+

-

SWITCHING 
POWER 
SUPPLY(DC)

V+ V- L N

-9-

Power cord Installation

Connect the plug of the connector of the power to the power outlet 

of the appliance.

Drain Hose Installation

1.Attach the hose inlet to the drain outlet located on the graph appliance.  

2.Allow the hose to be set off to a drain or a sink or even to a container 
that can collect the discharged water. 

Control Panel

Filter Maintenance

1. Unplug the unit.

2. Slide-out the filter from the side.

3.  Check  the  filter  for  dirt  and 

buildup.

4.  Clean 

the 

filter 

mesh 

by 

vacuuming it or washing with warm 

water (no soap or cleaners). Gently 

shake the filter dry then reinsert it. 

There is dirt or buildup, replace the 

filter.

MAINTENANCE

Wi-Fi connection successful.

Hotspot direct successful icon.

Connection to server failed

.

-8-

Unit Maintenance

• Always clean the surface of the housing with a damp cloth. Do not 

clean with water directly.

• Always store the machine in a day and cool indoor place, away 

from sunlight as well as chemicals and out of children’s reach.

When the unit is plugged in you will 
see the Abestorm LOGO. 

STARTUP

-4-

Press the POWER button to turn the dehumidifier ON and 

OFF.

 

Press the PURGE button to purge the machine.

Press the MENU button to advance to the next screen or to 

enter a value. 

 

Press the SET button to scroll through available values.

The machine displays when it is nat working. 
(Power off state but have electricity)

5

4

Summary of Contents for SLGR Elite

Page 1: ...fier User sManual Note as we keep upgrading our product we reserve the right to modify the product without natice in advance Abestorm Solutions INC Water Damage Series Add Berlin Tel 44 20 81243974 Email www abestorm com ...

Page 2: ...at can instant detect the room and provide instant feedback With a superior stacking and a heavy duty condensate pump These stackable dehumidifiers are the best drying system Read the operation and maintenance instructions carefully before using this unit Proper adherence to these instructions is essential to obtain maximum beneft from your Abestorm SLGR Elite dehumidifer It is designed to be used...

Page 3: ...our local installer or Contact Abestorm sales Abestorm com or 44 20 81243974 Electrical Supply Power Supply Outlet Requirement Citcuit protector WARNING Using a 220V outlet may cause serious injury from electric shock To reduce risk of injury 1 Always disconnect machine from electrical power before servicing 2 Only plug unit into a gounded electrical cicuit 3 Do not use an extension cord 4 Do not ...

Page 4: ...k or even to a container that can collect the discharged water Control Panel When the unit is plugged in you will see the Abestorm LOGO STARTUP Press the POWER button to turn the dehumidifier ON and OFF Press the PURGE button to purge the machine Press the MENU button to advance to the next screen or to enter a value Press the SET button to scroll through available values The machine displays when ...

Page 5: ...7 6 ...

Page 6: ...rt causes clogging in the system Instructions for use of filter 9 8 E1 Humidity Sensor or Communication Error Solution Check to ensure that the sensor wire is connected at both ends if no issues are visible the sensor may be faulty E4 Problem with Pump Solution Verify that the pump is properly installed and functioning If so unplug the unit for two minutes then restart Solution Increase the room t...

Page 7: ...r back and pour a cup of 8oz of an antifreeze reagent with Propylene glycol Put it via the heat exchanger It will stream into the reservoir of the pump Avoid purging the solution from the unit 5 If filters are dirty they should be replaced if the unit is going to be stored for a long time This precaution will prevent microbial from growing on the filter Technical Description The unit a system of r...

Page 8: ...y or the airflow is restricted 4 The front casing is not tied to the rear one I If the compressor runs with its air button turned off check if 1 The control board is defective AirMover The impeller causes the air to move If it is defective the whole assembly should be replaced 1 Remove the power cable from the power socket 2 Pull out the exhaust and the control board 3 Remove the impeller bracket ...

Page 9: ...nit from the power source 2 Remove the housing at the top 3 Disconnect the float switch cables from their harness 4 Remove the screw that ties the bracket of the pump to the housing at the bottom 5 Remove the float switch from the bracket by unscrewing The pump is activated by the float safety switch when the water level in the condensate pump has risen too high The switch is also responsible for ...

Page 10: ...r and palletizing 2 Reinstallation and removal of the unit will be done by the owner 4 The customer is also responsible for risks related to damage and loss while shipping If shipped customer is responsible for all risk of loss or damage 2 If there is a need for warranty service the customer should contact Abestorm Tech Support on to get an RA Return Authorization number 44 20 81243974 3 After you...

Page 11: ...ALLATION OR DESIGN FAILURE TO FOLLOW INSTRUCTIONS LACK OF NORMAL CARE TAMPERING MISUSE OR ABUSE WHETHER ACCIDENTAL OR INTENTIONAL FIRE HURRICANE STORM DAMAGE 3 ANY COSTS DUE TO LOST PROFIT OR DELAY 5 ANY ADDITIONAL COSTS DUE TO CHANGES IN LAWS OR BUILDING CODES 4 FREEZING 6 FREIGHT CHARGES 7 CORROSION 8 CAUSE BEYOND CONTROL 9 FILTERS 10 CONSUMABLE PARTS INCLUDING BUT NOT LIMITED TO SWITCHES POWER ...