Status Information
The receiver can provide you with a number of different types of Status Information. Available
Status Information is listed in the following table. To access the Status information, press the
RIGHT option button twice to get to the Main menu and use the UP or DOWN arrow button to
highlight System. Select System by pressing the RIGHT option button. Highlight and select Status
from the System menu.
Removed Sensor
Allows you to indicate you are removing a Sensor
so the Data Loss Alarm will not set off. Use this
only if you are removing a sensor.
Note:
Once you select this option, the system will
terminate any active sensor.
System Status
Shows information about the System, including
Sensor life remaining (in hours) and time since
valid data was transmitted (in hours).
Receiver Status
Shows information about the receiver, including
serial number and software version (may be useful
when calling Customer Care), as well as battery life
remaining.
Transmitter Status
Shows the transmitter’s serial number. You may need
to verify the serial number after linking to a new
transmitter. This unique value is used by the receiver
to accept data from only the transmitter the receiver
is linked to. It also shows battery life remaining.
After replacing the battery, once the system has
recognized the new battery, it will display battery life
as 75-100%. If there is no connection between the
transmitter and receiver, you will see 3 dashes, “- - -”,
instead of the battery life.
Status Information
Description
Customer Care: 1-866-597-5520
90
Section 10
Respond to Alarms, Errors, and Problems
08:30A
No Yes
Did You Remove
The Sensor?
System Status 08:30A
Sensor Life Left 000:000
Time Since
Sensor Data - - -
Back Main
Receiver Status 08:30A
Serial #: BAAH190-80020
SW Version: 0.61
Battery Life: 75-100%
Back Main
Transmitter Status 08:30A
Transmitter ID:
AAAH298-80008
TX Battery: 75-100%
Back Main
Summary of Contents for FreeStyle Navigator
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...1 Getting Acquainted ...
Page 23: ...2 Install or Replace Transmitter and Receiver Batteries ...
Page 29: ...3 Set the Time and Date ...
Page 34: ...Customer Care 1 866 597 5520 ...
Page 35: ...4 Perform a Control Solution Test ...
Page 42: ...Customer Care 1 866 597 5520 ...
Page 43: ...5 Insert or Remove Your Sensor ...
Page 54: ...Customer Care 1 866 597 5520 ...
Page 55: ...6 Attach Your Transmitter ...
Page 61: ...7 Calibrate Your System Test Blood Glucose Manually ...
Page 74: ...Customer Care 1 866 597 5520 ...
Page 75: ...8 Set Review or Change the Alarm Settings ...
Page 89: ...9 Daily Use ...
Page 96: ...Customer Care 1 866 597 5520 ...
Page 97: ...10 Respond to Alarms Errors and Problems ...
Page 119: ...11 Add Events ...
Page 125: ...12 Review Reports and Edit Events ...
Page 135: ...13 Clean Your System ...
Page 136: ...Section 13 Key Terms n Receiver n Transmitter n Contact Points Customer Care 1 866 597 5520 ...
Page 139: ...14 Link and Unlink Your Transmitter and Receiver ...
Page 144: ...Customer Care 1 866 597 5520 ...
Page 145: ...15 Reset User Settings ...
Page 146: ...Customer Care 1 866 597 5520 ...
Page 149: ...16 Change Country Settings ...
Page 155: ...17 Appendix A Site Maintenance ...
Page 158: ...Customer Care 1 866 597 5520 ...
Page 159: ...18 Appendix B Specifications ...
Page 173: ...19 Appendix C FCC Compliance Information ...
Page 174: ...Customer Care 1 866 597 5520 164 Section 18 Appendix B Specifications ...
Page 182: ...Customer Care 1 866 597 5520 ...
Page 183: ...20 Glossary ...
Page 184: ...Customer Care 1 866 597 5520 174 Section 19 Appendix C Classification Compliance Declaration ...
Page 191: ...21 Index ...
Page 192: ...Customer Care 1 866 597 5520 ...
Page 195: ......