![ABB UNO-2.0-I-OUTD Product Manual Download Page 61](http://html.mh-extra.com/html/abb/uno-2-0-i-outd/uno-2-0-i-outd_product-manual_4189061.webp)
- 61 -
000389AG
7 - Operation
The predefined setting is 0 / 0 and means no
grid standard is selected
and the display language is English (in this case, the “Set Country” mes-
sage will appear on the display).
If a position of switches not assigned on the display 12 is selected, “Inva-
lid Selection” appears.
G
rid standard of the country and display language saving
The settings become fixed after 24 hours of operation of the inverter (it
does not need to be connected to the grid, and only needs to be pow-
ered).
The time remaining before the settings become fixed can be seen in the
dedicated menu, and a notice appears if the time has expired.
Once the settings are fixed, turning the rotary switches will produce no effect. In this condi
-
tion, only the language can be changed through the dedicated menu.
At any time and for any reason, the ENGLISH
language of the display menu can be set by
simultaneously pressing the “ESC” and “ENTER” buttons for at least 3 seconds.
If it is necessary to change the standard of the country after the settings have been fixed
(after 24 hours of operation) please contact ABB’s technical support department with the part
number and serial number of the inverter to hand.
Set Country
Invalid Selection