Join connecting rods (81269) using screws (81272). When tensioning
screws (81272), ensure that connecting rods (81269) are located
correctly in recesses in filter silencer body (81135). Now alternately
tighten screws (81272) to following maximum torque:
Screw
tightening torque [Nm]
81272
20
Screw lock nuts (81273) onto screw (81272) and tighten to following
torque:
Lock nut
tightening torque [Nm]
81273
40
Fit filter strip (81265).
If provided