Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
Taking out of operation at short notice
9
Locking the rotor
9.2
Page 105
Sept
em
be
r 2
014
H
ZT
L24
98_
EN
R
ev
is
ion A
Further measures and information for operation with blocked rotor for 4-
stroke engines
4-stroke engine with one turbocharger
No further measures are necessary. The engine can be operated as a
naturally-aspirated engine according to the engine builder's instructions.
4-stroke engine with several turbochargers
No further measures are necessary on engines with separate air and
exhaust gas receivers. The engine can be operated as a naturally-
aspirated engine according to the engine builder's instructions.
If the engine is equipped with a common air receiver and separate
exhaust gas receivers, the bellows at the compressor outlet of the
damaged turbocharger must be removed and the air duct on the engine
side must be closed off. If this is not done, the undamaged turbocharger
can race under no load and run at overspeed.
Depending on the engine turbocharging system, more or less powerful
pulses from the exhaust gas system act on the locked rotor. The locking
device is then heavily stressed, particularly in the case of pulse charging
(turbine casing with more than one gas inlet). With this in mind, the
following operating limits should not be exceeded:
In systems similar to those with constant pressure (1 gas inlet), the
engine can be operated up to a maximum of 25% engine load. The
pressure in the charge air receiver must not exceed 0.9 bar
overpressure.
In the case of pulse charging (2...4 gas inlets), the engine can be
operated up to a maximum of 20% engine load. The pressure in the
charge air receiver must not exceed 0.5 bar overpressure.
CAUTION
Attention must always be paid to the speed of the undamaged
turbocharger. The speed limit n
Bmax
given on the rating plate must not
be exceeded.
Separate receivers
Common air receiver
© Copyright 2014 ABB. All rights reserved.