75
Technical data
EN
Terra 94 UL
Terra 124 UL
Terra 184 UL
User Interface
Display type
7” LCD (touch)
Display languages
English, French, Spanish
(others available via Software upgrade)
Authentication methods
RFID
Option: payment terminal
RFID system
Mifare ISO 14443 A/B to part 4 and ISO15693, ISO18092 / ECMA-
340 (NFC).
Others available on request (Calypso, Ultralight, PayPass, HID; and
more)
Energy metering
NIST
Connectivity
Embedded communication interface
Cellular, LAN
Cellular modem
4G / LTE
Communication Protocol
Open Charger Point Protocol (OCPP) 1.6 and 2.0
Standards
Mark of Conformity
cTUVus
Safety standards
UL 2202:2009 R2.18, CSA STD C22.2 No 107.1-16
EMC rating
Class A
FCC Standards
47 CFR FCC part 22, 24, 27 (3G and 4G), 47 CFR FCC part 15b
ISED Standard
RSS 132 + RSS 139 + RSS 199 (3G and 4G), ICES-003
Additional standards
CHAdeMO 1.2
DC plugs compliant with UL 2251: 2017 (R2022)
CSA C22.2 No. 282-17:2nd (R2022)
1. The heater will operate daily when the outside air reaches the dew point, to avoid condensation inside the
cabinet.
2. Min 0.94 at different output power and voltage
10.1.2 Environmental Conditions
Storage
(in the package)
Transportation
4
(in the package)
Installation
(Operation)
5
Environment type
Indoor
Weather-protected
3
Indoor and Outdoor
Ambient air temperature
23...104 °F (-5...+40 °C) -31...122 °F (-35...+50 °C) -31...122 °F (-35...50 °C)
derating from 104 °F (40 °C)
Relative Humidity
5...95% @ 86 °F (30 °C) 5...100% @ 80.6 °F (27 °C) 5...100% @ 80.6 °F (27 °C)
Altitude (without derating) -
-
6500 ft (2000 m)
Condensation
No
6
No
6
Yes
Wind-driven precipitation
No
No
Yes
Formation of ice
No
No
Yes
Maximum storage time
1
1 year
2
-
-
1. Starting from manufacturing date
2. Contact ABB if the EVSE has been stored for longer periods
3. Protected from the influences of meteorological conditions
4. Transportation conditions are those that the product can be exposed to while transported and handled in
its original package
5. EVSE powered on
6. Moderate condensation on the package may occasionally occur due to variations in temperature