74
“Operation and installation manual”
EN
10.1 Technical data
10.1.1 Technical data table
Terra 94 UL
Terra 124 UL
Terra 184 UL
EVSE configuration
Charging standard
Mode 4
Number of outputs
1 or 2 based on the configuration
Number of EV served
1
Up to two EV in
parallel
Up to two EV in
parallel
Available output connectors
CCS 1
/ NACS
/ CHAdeMO
Cable type
Air cooled cable
Available cable Length
6 m (20 ft)
Efficiency
> 96% @ 715 V DC
DC Output
Rated power
90 kW
120 kW
180 kW
Rated voltage
CCS 1
: 150...920 V
NACS
: 150...920 V
CHAdeMO
: 150...500 V
Max output current
CCS 1
: 400 A
NACS:
400 A
CHAdeMO:
200 A
AC Input
Connection type
3Ø + PE (WYE System)
Rated voltage
480 V ± 10%
Rated frequency
60 Hz ± 5%
Rated current
115 A
153 A
230 A
Max current @ Min. AC voltage
(480 V - 10%)
126 A
168 A
253 A
Rated power
94.7 kW
125.9 kW
189.4 kW
Max short circuit current
65 kA
Power Factor
> 0.99 @ rated DC power
Total Harmonic Distortion (THD)
< 5 %
Stand-by active power
50 W (heater off) / 900 W (heater on
1
)
Protection
Overcurrent, overvoltage, undervoltage, ground fault including DC
leakage protection, overtemperature, integrated SPD
SPD
Yes, Type 2
Tilt sensor (optional)
Voltage input
20..24 V DC
Current consumption
Maximum 30 mA
Protection
Reverse polarity
Mechanical
Dimensions (W x H x D)
Without CMS: 1’ 10” x 6’ 28” x 2’ 10” (565 x 1900 x 880 mm)
With both CMS: 2’ 09” x 6’ 28” x 3’ 03” (847 x 1900 x 922 mm)
Mounting Type
Floor mounted
Weight
772 lbs (350 kg)
800 lbs (365 kg)
870 lbs (395 kg)
Weight with packaging
849 lbs (385 kg)
877 lbs (398 kg)
947 lbs (430 kg)
Weight of each optional CMS
75 lb (34 kg)
Enclosure type
Stainless steel 430 and Aluminum
IK rating
IK10 (Display: IK08)
Lifting points
4 x eyebolts (on the top of the EVSE)
Environmental
Ingress protection
Rain test (according to UL2202)
Environmental type
Indoor and Outdoor
Pollution degree
3 Outside (2 Inside)
Noise level
< 62 dB(A) @ 3.2 ft (1 m), 77 °F (25°C), full power (on front door)