Ethernet cable
Parameter
Specification
Ethernet type
RJ45
Cable type
8P + PE, shielded
Example of a cable for distance of 75 m
or less
HELUKAT 600E
Bandwidth, upload
Minimum 128 kbit/s
Bandwidth, download
Minimum 4 Mbit/s
Availability
99.9%
8.12
AC input specifications
8.12.1
General AC input specifications
Parameter
Specification
Input AC power connection
3P + N + PE
Earthing systems
TN-S
TN-C
TN-C-S
IT
Input voltage range
400 VAC +/- 10% (50 Hz or 60 Hz)
Power factor at full load
> 0.96
Efficiency
> 94% at nominal output power
Total harmonic distortion (current)
< 5%
8.12.2
AC input cable
Parameter
Specification
Cable shielding (optional)
If the local rules require shielded cables,
the cable shielding must be connected
to the PE rail at both ends of the cable.
Diameter of the phase conductors
Refer to the local rules.
Diameter of the PE conductor
The same as the diameter of the phase
conductors
Surface
minimum 150 mm²
Diameter, including shielding
34 to 45 mm
8.12.3
Terra 94
Parameter
Specification [A]
Maximum rated input current
140
Technical data
BCM.S1102.0-EN | 001
45