Procedure
1. Prepare the wires:
a. Cut the wires (A) to (D) so they can
reach the connectors on the
manual switch (E).
b. Strip the insulation from the end
or the wires. Make sure that the
strip length agrees with the wire
end rings.
c. Attach the wire end rings (F) to the
end of the wires. Use the wire end
ring tool.
2. Attach the wires to the connectors:
•
Brown L1 wire (A) to the connector
(H)
•
Black L2 wire (B) to the connector (I)
•
Gray L3 wire (C) to the connector (J)
•
Blue neutral wire (D) to the connector (K)
Use the fasteners (G).
3. Tighten the fasteners to the correct torque. For the specification, refer to
section
.
5.6.3
Connect the PE wire
Preliminary requirements
1.
The front and right doors
are open.
•
Wire end ring M11
•
Fasteners M11
•
Wire stripper pliers
•
Wire end ring tool
•
Torque socket wrench
•
Procedure
1. Prepare the wire:
a. Cut the PE wire (A) so that it can
reach the PE busbar (B).
b. Strip the insulation from the end
or the wire. Make sure that the
strip length agrees with the wire
end ring.
c. Attach the wire end ring (C) to the
end of the wire. Use the wire end
ring tool.
2. Attach the PE wire to the PE busbar.
Use the fasteners (D).
3. Tighten the fasteners to the correct
torque. For the specification, refer to
section
.
K
J
I
H
A
B
C
D
E
G
F
B
A
D
C
Installation
BCM.S1102.0-EN | 001
31