TEIP11, TEIP11-PS 

 

1

 

Safety 

 

Change from one to two columns 

1.1

 

General information and instructions 

These instructions are an important part of the product and 
must be retained for future reference. 
Installation, commissioning, and maintenance of the product 
may only be performed by trained specialist personnel who 
have been authorized by the plant operator accordingly. The 
specialist personnel must have read and understood the 
manual and must comply with its instructions. 
For additional information or if specific problems occur that are 
not discussed in these instructions, contact the manufacturer. 
The content of these instructions is neither part of nor an 
amendment to any previous or existing agreement, promise or 
legal relationship. 
Modifications and repairs to the product may only be 
performed if expressly permitted by these instructions. 
Information and symbols on the product must be observed. 
These may not be removed and must be fully legible at all 
times. 
The operating company must strictly observe the applicable 
national regulations relating to the installation, function testing, 
repair and maintenance of electrical products. 
 

1.2

 

Warnings 

The warnings in these instructions are structured as follows: 
 

DANGER 

The signal word "DANGER" indicates an imminent danger. 
Failure to observe this information will result in death or 
severe injury. 

 

WARNING 

The signal word "WARNING" indicates an imminent danger. 
Failure to observe this information may result in death or 
severe injury. 

 

CAUTION 

The signal word "CAUTION" indicates an imminent danger. 
Failure to observe this information may result in minor or 
moderate injury. 

 

NOTICE 

The signal word "NOTICE" indicates useful or important 
information about the product. 
The signal word "NOTICE" is not a signal word indicating a 
danger to personnel. The signal word "NOTICE" can also 
refer to material damage. 

 

 

 

1.3

 

Intended use 

I/P signal converters for standard signals TEIP11 and TEIP11-
PS are used to control pneumatic actuators or pneumatic 
positioners for positioning valves. 
 
The device has been designed for use exclusively within the 
technical limit values indicated on the name plate and in the 
data sheets. 
 

1.4

 

Improper use 

The following are considered to be instances of improper use 
of the device: 
—  For operating as a flexible adapter in piping, e.g. for 

compensating pipe offsets, pipe vibrations, pipe 
expansions, etc. 

—  For use as a climbing aid, e.g. for mounting purposes 
—  For use as a support for external loads, e.g. as a support 

for piping, etc. 

—  Material application, e.g. by painting over the housing, 

name plate or welding/soldering on parts. 

—  Material removal, e.g. by spot drilling the housing. 
 

1.5

 

Warranty provisions 

Using the device in a manner that does not fall within the 
scope of its intended use, disregarding this manual, using 
underqualified personnel, or making unauthorized alterations 
releases the manufacturer from liability for any resulting 
damage. This renders the manufacturer's warranty null and 
void. 
 

 

 

Summary of Contents for TEIP11

Page 1: ...Operating Instruction 42 18 46 EN Rev L TEIP11 TEIP11 PS I P signal converter...

Page 2: ...ional documentation on TEIP11 TEIP11 PS is available for download free of charge at www abb com positioners Alternatively simply scan this code Manufacturer ABB Automation Products GmbH Measurement An...

Page 3: ...nting 8 3 2 2 Control room housing unit for block mounting 8 3 2 3 Field mount housing 8 4 Product identification 9 4 1 Name plate 9 4 2 Scope of delivery 9 4 2 1 Accessories 9 5 Transport and storage...

Page 4: ...al word WARNING indicates an imminent danger Failure to observe this information may result in death or severe injury CAUTION The signal word CAUTION indicates an imminent danger Failure to observe th...

Page 5: ...that corresponds to the minimum ambient temperature Versions with an intrinsically safe control head may no longer be operated as intrinsically safe if they have been previously operated with the fla...

Page 6: ...xplosion if the device is operated with the housing or terminal box open Before opening the housing or the terminal box note the following points Check that a valid fire permit is available Make sure...

Page 7: ...signal flowing through the coil A counterforce is applied on the other side of the lever arm through the dynamic air pressure present at the nozzle and the flapper The force is controlled in such a w...

Page 8: ...nit for block mounting enables you to install a number of converters in a small space This design features central air supply via connection block and stop valves in the air connectors of the integrat...

Page 9: ...sport documents All claims for damages must be submitted to the shipper without delay and before installation 5 2 Storage conditions Bear the following points in mind when storing devices Store the de...

Page 10: ...ls that are mounted in a horizontal position the electrical connection for the device should preferably be facing up 6 1 2 Control room housing unit for block mounting For this design a special connec...

Page 11: ...steel field mount housing 1 Terminal for signal input covered 2 Cable entry 3 Supply air connection 4 Output covered Installation instructions Position the housing so that the cable gland is facing d...

Page 12: ...onductor cross sections up to a maximum of 2 5 mm2 14 AWG Do not reverse the polarity when connecting the signal line Control room housing unit for rail and block mounting The terminals are located on...

Page 13: ...i 1 Output signal 0 2 1 bar 3 15 psi 0 4 2 bar 6 30 psi 1 1 Only valid for option 509 increased input signal Air consumption 0 2 kg h 0 16 Nm3 h 0 1 scfm 7 Commissioning Once the installation is compl...

Page 14: ...acc to page 2 for nearest service location 10 Recycling and disposal 10 1 Disposal NOTICE Products that are marked with this symbol may not be disposed of through municipal garbage collection points...

Page 15: ...ls Company Address Contact person Telephone Fax E Mail Device details Typ Serial no Reason for the return description of the defect Was this device used in conjunction with substances which pose a thr...

Page 16: ...16 42 18 46 EN Rev L TEIP11 TEIP11 PS 12 1 Control Document 12 1 1 Connection diagram 900842 FM...

Page 17: ...TEIP11 TEIP11 PS 42 18 46 EN Rev L 17...

Page 18: ...18 42 18 46 EN Rev L TEIP11 TEIP11 PS 12 1 2 Connection diagram 900842 CSA...

Page 19: ...TEIP11 TEIP11 PS 42 18 46 EN Rev L 19...

Page 20: ...positioners Note We reserve the right to make technical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB do...

Reviews: