3UHSDULQJWKHHTXLSPHQW
2.4. Checking of sensors
35
3HAC 16578-1 Revision: E
© Copyri
ght
200
3-2007 ABB.
All rights reserved.
4. Remove the sensor, turn it 180° and refit it
in the corresponding hole pattern. wait a
couple of seconds until the sensor has
been stabilized.
1RWH'RQRWFKDQJHWKHSRVLWLRQRIWKH
FDOLEUDWLRQSODWH
xx0300000261
5. Read the values for “A” and “B” shown by
the instrument. The difference between the
two readings should be less than 0.002°
and have opposite directions (+/-). If the
difference is greater, the sensor must be
recalibrated.
.
$FWLRQ
1RWH,OOXVWUDWLRQ
&RQWLQXHG