All the LEDs are tested by turning them on simultaneously. The LCD shows a
set of patterns so that all the pixels are activated. After the test, the display
returns to normal state.
5.2
Indication messages
5.2.1
Internal faults
When the Ready LED indicates an internal fault by flashing, the message
associated with the fault is found in the internal event list in the LHMI menu
Main
menu/Monitoring/Internal events
. The message includes the date, time,
description and signal state for the fault. The internal event list is not updated
dynamically. The list is updated by leaving the
Internal events
menu and then
selecting it again. The current status of the internal fault signals can also be
checked via the LHMI in
Main menu/Monitoring/IED status
.
Different actions are taken depending on the severity of the fault. After the fault is
found to be permanent, the IED stays in internal fault mode. The IED continues to
perform internal tests during the fault situation.
When a fault appears, the fault indication message is to be recorded and stated
when ordering service.
Table 3:
Internal fault indications
Fault indication
Additional information
Internal Fault
Real Time Clock Error
Hardware error with the real time clock.
Internal Fault
Runtime Exec. Error
One or more of the application threads
are not working properly.
Internal Fault
SW Watchdog Error
This signal will be activated when the
terminal has been under too heavy load
for at least 5 minutes.
Internal Fault
Runtime App Error
One or more of the application threads
are not in an expected state.
Internal Fault
File System Error
A file system error has occurred.
Internal Fault
TRM-Error
A TRM card error has occurred. The
instance number is displayed at the end
of the fault indication.
Internal Fault
BIO-Error
A BIO card error has occurred. The
instance number is displayed at the end
of the fault indication.
Internal Fault
COM-Error
A COM card error has occurred. The
instance number is displayed at the end
of the fault indication.
Internal Fault
PSM-Error
A PSM card error has occurred. The
instance number is displayed at the end
of the fault indication.
1MRS756801 A
Section 5
Troubleshooting
630 series
31
Commissioning Manual