28. Functions, codes and symbols
Table 126. Functions included in the relay
Description
IEC 61850
IEC 60617
ANSI
Protection
Three-phase non-directional overcurrent protection, low stage
PHLPTOC
3I>
51P-1
Three-phase non-directional overcurrent protection, high stage
PHHPTOC
3I>>
51P-2
Three-phase non-directional overcurrent protection,
instantaneous stage
PHIPTOC
3I>>>
50P/51P
Voltage dependent overcurrent protection
PHPVOC
I(U)>
51V
Three-phase directional overcurrent protection, low stage
DPHLPDOC
3I> ->
67-1
Three-phase directional overcurrent protection, high stage
DPHHPDOC
3I>> ->
67-2
Non-directional earth-fault protection, low stage
EFLPTOC
I0>
51N-1
Non-directional earth-fault protection, high stage
EFHPTOC
I0>>
51N-2
Non-directional earth-fault protection, instantaneous stage
EFIPTOC
I0>>>
50N/51N
Directional earth-fault protection, low stage
DEFLPDEF
I0> ->
67N-1
Directional earth-fault protection, high stage
DEFHPDEF
I0>> ->
67N-2
Third harmonic based stator earth-fault protection
H3EFPSEF
dUo(3H)>/Uo(3H)<
27/59THD
High-impedance based restricted earth-fault protection
HREFPDIF
dI0Hi>
87NH
Rotor earth-fault protection
MREFPTOC
Io>R
64R
Negative-sequence overcurrent protection for machines
MNSPTOC
I2>G/M
46G/46M
Three-phase thermal overload protection, two time constants
T2PTTR
3Ith>T/G
49T/G
Three-phase current inrush detection
INRPHAR
3I2f>
68
Transformer differential protection for two-winding transformers TR2PTDF
3dI>T
87T
High-impedance or flux-balance based differential protection for
machines
MHZPDIF
3dIHi>G/M
87GH/87MH
Stabilized differential protection for machines
MPDIF
3dI>G/M
87G/87M
Three-phase overvoltage protection
PHPTOV
3U>
59
Three-phase undervoltage protection
PHPTUV
3U<
27
Positive-sequence overvoltage protection
PSPTOV
U1>
47O+
Positive-sequence undervoltage protection
PSPTUV
U1<
47U+
Negative-sequence overvoltage protection
NSPTOV
U2>
47O-
Residual overvoltage protection
ROVPTOV
U0>
59G
Directional reactive power undervoltage protection
DQPTUV
Q>-->,3U<
32Q,27
Reverse power/directional overpower protection
DOPPDPR
P>
32R/32O
Underpower protection
DUPPDPR
P<
32U
Frequency gradient protection
DAPFRC
df/dt>
81R
Overfrequency protection
DAPTOF
f>
81O
Underfrequency protection
DAPTUF
f<
81U
Low voltage ride through protection function
LVRTPTUV
U<RT
27RT
Overexcitation protection
OEPVPH
U/f>
24
Generator Protection and Control
1MRS757583 C
REG630
Product version: 1.3