Table 109. Number of ANDQT instances
Logic block
Quantity with cycle time
3 ms
8 ms
100 ms
ANDQT
-
20
100
Table 110. Number of INDCOMBSPQT instances
Logic block
Quantity with cycle time
3 ms
8 ms
100 ms
INDCOMBSPQT
-
10
10
Table 111. Number of INDEXTSPQT instances
Logic block
Quantity with cycle time
3 ms
8 ms
100 ms
INDEXTSPQT
-
10
10
Table 112. Number of INVALIDQT instances
Logic block
Quantity with cycle time
3 ms
8 ms
100 ms
INVALIDQT
-
6
6
Table 113. Number of INVERTERQT instances
Logic block
Quantity with cycle time
3 ms
8 ms
100 ms
INVERTERQT
-
20
100
Table 114. Number of ORQT instances
Logic block
Quantity with cycle time
3 ms
8 ms
100 ms
ORQT
-
20
100
Table 115. Number of PULSETIMERQT instances
Logic block
Quantity with cycle time
Range or Value
Accuracy
3 ms
8 ms
100 ms
PULSETIMERQT
-
10
30
(0.000–90000.000) s
±0.5% ±10 ms
Table 116. Number of RSMEMORYQT instances
Logic block
Quantity with cycle time
3 ms
8 ms
100 ms
RSMEMORYQT
-
10
30
1MRK 505 346-BEN -