nstallation procedure for quick-fit connectors
,QWKHLQYHUWHUPRGHOVZKHUHWKHTXLFN¿WFRQQHFWRUVDUHXVHGLVSRVVL
-
EOHWR¿QGRQHRIWKHIROORZLQJIRXUW\SHV
- Weidmüller PV-Stick
- Weidmüller WM4
- MultiContact MC4
- Amphenol H4.
Please refer to the document “
String inverters – Product manual ap-
pendix
” available at
www.abb.com/solarinverters
for information on the
TXLFN¿WFRQQHFWRUEUDQGDQGPRGHOXVHGLQWKHLQYHUWHU
The model of connectors installed on your inverter must be matched by
the same model of the respective corresponding parts to be used (che-
cking the conforming corresponding part on the manufacturer's website
or with ABB).
8VLQJFRUUHVSRQGLQJSDUWVWKDWDUHQRWFRPSOLDQWZLWKWKHTXLFN¿WFRQQHFWRUPRGHOVRQWKH
inverter could cause serious damage to the unit and lead to invalidation of the warranty.
&$87,217RDYRLGGDPDJHWRWKHHTXLSPHQWZKHQDWWDFKLQJFDEOHVSD\SDUWLFXODUDWWHQ
-
tion to polarity.
:(,'0h//(5396WLFNTXLFN¿WFRQQHFWRUV
Installation of Weidmüller PV-Stick connectors does not require any spe-
cial tooling.
- Strip the cable to which you want to apply the connector (after verifying
that it complies with the connector limits).
- Insert the wire into the connector until you hear a locking "click".
Click !
3 ... 4 Nm
0 !
- Tighten the knurled ring nut for optimal clamping.
15...16.5mm
4...6mm
5.5...7.5mm
2