- 123 -
000843DG
7 - Operation
DIGITAL OUTPUTS:
In the
Digital Outputs
menu it’s possible to set the activation status
of the two configurable relays related to “ALARM” and “AUX” terminal
block
33
(refer to “Configurable Relay connection (ALARM and AUX)”
chapter to know how to connect to these terminal block) and to configure
customised alarm conditions.
This contact can be used, for example, to activate a siren or a visual
alarm, control the disconnect device of an external transformer, or
control an external device.
Relay switching can be set in different modes using the setting icon :
With “Output active filter” you can select the list of events for which the relays
switch.
The available operating mode are:
1. Production
The relay is activated (status: switched) whenever the inverter connects
to the grid; as soon as the inverter is disconnected from the grid (for
whatever reason that caused disconnection), the relay is in its resting
position.
2. Alarm ALL - no-latch
The relay is activated (status: switched) whenever an error (code Exxx)
or warnings related to grid parameters out of range (Warning – codes
W003, W004, W005, W006, W007) are present on the inverter. The
alarm contact returns to its resting position when the alarm signal ends,
i.e. before the inverter checks the grid parameters after the alarm state.
This is because grid control state is not an alarm state but a state of nor-
mal operation.
Alarms for which the relay is activated
E001
E002
E003
E004
E005
E006
E007
E009
E010
E011
E012
E013
E014
E015
E016
E017
E018
E019
E020
E021
E022
E023
E024
E025
E026
E027
E028
E029
E030
E031
E032
E033
E034
E035
E036
E037
E046
E050
E053
E054
E055
E056
E057
E058
E077
E078
E081
E084
E089
W003
W004
W005
W006
W007
In the presence of W003, W004, W005, W006, W007 signalling, the
alarm contact switches to then reset itself at the end of the alarm signal.
This means that during the absence of grid voltage (display message
“Missing Grid”) the alarm contact remains in its resting position.
INVERTER RUN
- PRODUCTION -
GRID DISCONNECTION
- NO PRODUCTION -
GRID RECONNECTION
t=based on Country Standard
DISCONNECTION
CAUSE IS STILL
PRESENT
Yes
No
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
Relay State:
Idle
Relay State:
Idle
Relay State: Switched
INVERTER RUN
ERROR OCCURENCY
ERROR MESSAGE
t=15s
GRID RECONNECTION
t=based on Country Standard
ERROR
STILL
PRESENT
Yes
No
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
Relay State:
Idle
Relay State:
Idle
Relay State: Switched