WaterMaster
Electromagnetic flowmeter
2 Parameter Tables
42
IM/WMPBST–EN Rev. B
43 / 27
LINING_MATERIAL
Material type of the sensor lining.
0: PTFE
1: Tefzel ETFE
2: PEEK
3: Hard Rubber
4: Linatex
5: Elastomer
6: Elastomer ACS
7: Elastomer NSF61
8: POMC
9: PFA
10: PPS
11: Soft Rubber
12: Polyurethane
13: Polypropylene
14: THICK PTFE
15: Ceramic Carbide
16: FEP
17: Neoprene
18: Other
Unsigned 8
1
D
r / C / a
Polyurethane
44 / 28
SENSOR_RUN_HOURS
Number of hours the sensor has been in use.
VisibleString
20
D
r / C / a
’? ’
45 / 29
TRANSMITTER_TYPE
Used to distinguish between ProcessMaster and WaterMaster transmitter types.
0: WaterMaster
1: ProcessMaster
Unsigned 8
1
D
r / C / a
WaterMaster
46 / 30
TX_TAG
Customer-assigned textual description of the transmitter.
VisibleString
20
S
r,w / C / a
’? ’
47 / 31
TX_ID
Unique factory-assigned identification number of the transmitter.
Unsigned 32
4
D
r / C / a
1
48 / 32
TX_PIN
PIN used in generation of service level access rights code.
Unsigned 16
2
D
r / C / a
1
49 / 33
TRANSMITTER_SAP_ERP_NUMBER
Transmitter SAP / ERP number.
VisibleString
20
Cst
r / C / a
’? ’
50 / 34
TRANSMITTER_SOFTWARE_VERSION
Transmitter firmware version number.
VisibleString
20
Cst
r / C / a
’? ’
51 / 35
APPLICATION_CRC
CRC of transmitter firmware.
VisibleString
20
Cst
r / C / a
’? ’
52 / 36
BOOTLOADER_VERSION_NUMBER
Transmitter bootloader firmware version number.
VisibleString
20
Cst
r / C / a
’? ’
53 / 37
TRANSMITTER_HARDWARE_VERSION_NUMBER
Version string of the transmitter hardware.
VisibleString
20
D
r / C / a
’? ’
54 / 38
PCB_VERSION_CODE
Version number of the transmitter hardware.
Unsigned 8
1
Cst
r / C / a
0
55 / 39
TRANSMITTER_RUN_HOURS
Number of hours the transmitter has been in use.
VisibleString
20
D
r / C / a
’? ’
Abs. Idx /
Rel. Idx
Variable Name / Brief Description
Data Type
Size
Store
Access /
Usage /
Transport
Default
Table 2.11 Slot 9 – Transducer Block 2 – Device Info (Continued)