8
FEP630, FEH630
ELECTROMAGNETIC FLOWMETER | CI/FEP630/FEH630-EN REV. D
… 3 Transport and storage
… Transport
G12034
Figure 3: Transport instructions -
á
DN 450
Flange devices
á
DN 450
• Use carrying straps to transport flange designs smaller than
DN 450.
• Wrap the carrying straps around both process connections
when lifting the device.
• Chains should not be used, since these may damage the
housing.
Flange devices > DN 450
G10645
Figure 4: Transport instructions - > DN 450
• Using a forklift to transport flange device can dent the
housing.
• Flange devices must not be lifted by the center of the
housing when using a forklift for transport.
• Flange devices must not be lifted by the terminal box or by
the center of the housing.
• Only the transport lugs fitted to the device can be used to lift
the device and insert it into the piping.
Storing the device
Bear the following points in mind when storing devices:
• Store the device in its original packaging in a dry and
dust-free location.
• Observe the permitted ambient conditions for transport
and storage.
• Avoid storing the device in direct sunlight.
• In principle, the devices may be stored for an unlimited
period. However, the warranty conditions stipulated in
the order confirmation of the supplier apply.
Temperature data
Storage temperature range
Æ
40 to 70 °C (
Æ
40 to 158 °F)
The ambient conditions for the transport and storage of the
device correspond to the ambient conditions for operation of
the device.
Adhere to the device data sheet!
Returning devices
Use the original packaging or a secure transport container of an
appropriate type if you need to return the device for repair or
recalibration purposes.
Fill out the return form (see
Return form
on page 81) and include
this with the device.
In accordance with the EU Directive governing hazardous
materials, the owner of hazardous waste is responsible for its
disposal or must observe the following regulations for shipping
purposes:
All devices delivered to ABB must be free from any hazardous
materials (acids, alkalis, solvents, etc.).
Address for returns:
Please contact Customer Center Service according to page 6 for
nearest service location.