Parameterization overview (factory settings)
Parameter Value
range
Factory setting
Sensor Tag
Alphanumeric, maximum 20 characters.
None
Sensor Location Tag
Alphanumeric, maximum 20 characters.
None
Qv Max 1
Depending on the nominal diameter of the sensor.
Set to Q
max
DN in accordance with
Measuring range
table
on page 54.
Unit Volumeflow Qv
l/s; l/min; l/h; ml/s; ml/min; m3/s; m3/min; m3/h; m3/d;
hl/h; g/s; g/min; g/h; kg/s; kg/min; kg/h; kg/d; t/min;
t/h; t/d
l/min
Unit Vol. Totalizer
m3; l; ml; hl; g; kg; t
Liter (l)
Pulses per Unit
1 to 10000
1
Pulse Width
0.1 to 2000 ms
100 ms
Damping
0.02 to 60 s
1
Operating mode Digital output 41 / 42 Off, Binary output, Pulse output, Frequency output
Digital output 41/42 as pulse output for forward flow
and reverse flow
Operating mode Digital output 51 / 52 Off, Binary output, pulse output (follows digital output
41 / 42, 90 ° or 180 ° out of phase)
Digital output 51 / 52 as binary output for output of
the flow direction.
Curr.Out 31/32
4-20mA FWD/REV, 4-20mA FWD, 4-12-20 mA
4-20mA FWD/REV
Curr.Out at Alarm
High Alarm 21 to 23 mA or Low Alarm 3.5 to 3.6 mA
High Alarm, 21.8 mA
Current at flow rate> 103 % (I=20.5 mA) Off (current output remains at 20.5 mA), High Alarm, Low
Alarm ,
Off
Low flow cutoff
0 to 10 %
1 %
Empty pipe detection
On / Off
Off
Software history
In accordance with NAMUR recommendation NE53, ABB offers a transparent and traceable software history.
Device software package FEx630 (device firmware package)
Design
Issue date
Type of change
Description
Ordering number
00.04.00 2/3/2017
First
publication –
3KXF002044U0100_00.04.00
00.04.01
6/27/2017
Bug fixing
Piston pumps filter
3KXF002044U0100_00.04.01
00:05:00
1/12/2018
Bug fixing
Integrated Polish language
3KXF002044U0100_00.05.00
7/1/2000
2018
Bug fixing
PROFIBUS DP® and Modbus® integrated. New bootloader
3KXF002044U0100_01.07.00
Change from one to two columns