  Circuit electric supply

  Pyroelectric motion sensor (PIR)

Introduction

The  Detector  of  Motion  is  a  device  for  interiors  completely  automatic  capable  of  controlling  up  to 

1200W of incandescent lamps or 320vth of fluorescent lamps. It is not only a lighting controller; it also 

has the capacity of detecting light movements in a 3 m radio around the sensor. It will also keep the 

lighting connected even when you are at the phone detecting your little movements. It also includes 

the lighting memory function, which means that the sensor is able to register and memorize the level 

of lux when connecting the lighting with the Motion Micro Sensor. 

Therefore once the level of lux is greater, even if the movement continues, the sensor will disconnect 

the interior lighting lamp, thus saving energy.

Simply taking full advantage of its versatile functionality, you can enjoy the comfort of its appropriate 
design.

Note: Please read this manual completely before installing the system.

Safety Cautions

 

Be sure to disconnect the mains power supply before you install the 

device.

  Make sure cabling power comes from a circuit with a magneto-thermal 

switch appropriate to the load, to perform the short circuit protection or 

from a suitable fuse.

  The detector is designed to be placed in the roof.

FIGURE 1

The installation of this device should be performed by a qualified electric technician

Choosing an assembly location

  Avoid locating the detector along with heating sources, devices of air conditioning and objects 

that are able to rapidly change temperature.

  Before assembling it, take into account that the motion sensor is more sensitive to the 

movement produced obliquely to the field and less sensitive to the frontal movement towards 

the detector.

SENSOR LESS SENSITIVE

MORE SENSITIVE SENSOR

FIGURE 2

Note: The detection of little movements can be realized inside a 3 m radio around the sensor, the usual 

movement can be detected in a 8m radio around the sensor.

Installation

To facilitate the installation it is essential to have ready an auger and a screwdriver.

Select a location for the unit based on the coverage angles shown in the

2.5~3.5m

12~16M

6~8m

FIGURE 3.

Cabling Instructions

(1) Disconnect the power network supply.

(2) With a flat end screwdriver, separate the motion sensor from the power and electric supply device.

FIGURE 4

Roof Motion Detector

N9611.71

Installation instructions and operation

When only one motion detector is connected to the load, the connection is as follows:

L
N

R2

S1

5A

FIGURE 5a

When two motion detectors are connected to the load, the connection is as follows:

L
N

R2

S1

5A

R2

S2

5A

FIGURE 5b

The motion detector is equipped with two relay outputs with main different functions:

Output 1 : Lighting / domestic applications.

Spinning roulette R1 is designed to set the timer output-1. It allows you to control lighting or domestic 

applications of the house for a maximum consumption of 1200W.

Product 2:  Dry Contact.

The spinning roulette R2 is designed to set the output-2 timer. It allows you to control any domestic 

application up to a maximum current of 2A.

At the end of the cabling and connection, place the power equipment in the ceiling’s flush mounting 

box and secure it with screws. Then insert the motion sensor in the power equipment

FIGURE 6

Lighting system adjustment

Please test the operation of the motion detector:

Test Mode :

  Place the spinning controls R1, R2 and LUX (the LUX lighting control) at the start of the line in 

the test position.

R1

R2

LUX

T

FIGURE 7

  The detector connection to the electric power network needs at least one minute of preheating 

until the outputs then disconnect.

  The outputs connect when walking through the detection area. When the movement stops the 

outputs keep connected during one second and then disconnect.

(1) TIMER ADJUSTMENTS (R1 y R2)

  The timer adjustment to the disconnection controls the time the relay outputs will keep 

connected after the detection. There are two adjustment spinning roulettes – R1 and R2 with 

different adjustment times.

  The adjustment rage of R1 is from 5 seconds to 12 minutes, while the R2 range is from 10 

seconds to 30 minutes. (FIGURE 8)

R1

R1

over 5 sec.

over 10 sec.

over 12 min.

over 30 min.

R2

R2

FIGURE 8

Note: When selecting 

, a short pulse of time is produced in the corresponding output relay contact. 

This allows controlling the general timer of the staircase light for example. 

(2) LIGHTING ADJUSTMENT (LUX)

When  the  automatic  operation  mode  is  enabled,  the  LUX  lighting  adjustment  spinning  roulette 

determines to what level of lighting starts working the R1 timer associated with output-1. 

Spinning roulette R2 associated with exit-2 does not depend on the illumination level adjusted on 

spinning roulette LUX. Works at any level of illumination.

When  the  LUX  lighting  spinning  roulette  level  adjusts  to  the  position  “T”,  the  output  will  always 

activate, day or night. When changing the roulette position to the other end, to the moon position, the 

output is activated only at night.

LUX

T

LUX

T

FIGURE 9

Operation

(1) AUTOMATIC OPERATION:

After at least 1 minute of preheating period, after connecting the detector to a power network, the 

sensor will be working according to the adjustments position R1, R2 and LUX.

(2) LIGHTING MEMORY

In  automatic  mode,  the  motion  detector  detonates  with  the  movement  and  automatically  registers 

and memorizes the initial lighting level. When the ambient light “seen” by the detector is 1,5 times the 

memorized initial level, the detector disconnects the output and thus saves energy.

This  feature  is  only  valid  for  output  1  associated  to  the  spinning  roulette  R1  which  adjusts  the 

temporization to the disconnection and for timers greater than one minute. The spinning roulette for 

the lighting level adjustment is irrelevant in this use.

Specificacions

Electric supply

CA 220 ~ 240V / 50Hz

Operation charge with R1 (Maximum)

1200W resistant or 320VA  

Fluorescence

Operation charge R2 (Dry contact)

Max. 2A, 230VCC/30VCC

Detection angle

360° at 20°C

Detection range (Micro movement)

3~4m radio at 20°C

Detection range (Regular movement)

6~8m radio at 20°C

Recommended assembly height

2,5~3,5m in roof

Adjustment timings

R1: 5 sec. ~ 12 min. 

R2: 10 sec. ~ 30 min.

Lux Adjustment

Yes

Lux Memory

Yes

Heating time

At least 1 min.

Protection

II

GUARANTEE

All  devices  manufactured  or  distributed  by  Asea  Brown  Boveri  S.  A.  Fábrica  Niessen  are  made 

according to the most modern technology.

The NIESSEN factory guarantees its articles within the supply general terms, provided that it is a 

manufacturing defect. In this case, please send the defective equipment to the distributor where it was 

acquired, accompanied by the certificate of guarantee.

Coverage

The present guarantee applies to those articles with a manufacturing defect. Therefore, it will not be 

applied to articles presenting damage as a result of not following correctly the assembly instructions 

or when the installation has been completed by non specialized personnel.

Also are excluded damages caused by device misuse and breakdowns produced in the transport.

Validity

The duration of this guarantee is 24 months, to be count from the date of acquisition of the device.

- Date of acquisition:

- Stamp and signature of distributor:

Important: Be sure that the present certificate of guarantee is duly fulfilled by the distributor.

SPA 
POR 

ENG 

FRA 
RUS

Asea Brown Boveri, S.A.

Fabrica NIESSEN

Polígono Industrial Aranguren, nº 6

20180 OIARTZUN - España

Telf. 943 260 101

Fax  943 260 250

e-mail: [email protected]

www.abb.es/niessen

79N961

10

 - 

2

Summary of Contents for NIESSEN N9611.71

Page 1: ...iluminación LUX al inicio del recorrido en posición de prueba R1 R2 LUX T FIGURA 7 La conexión del detector a la red eléctrica de alimentación necesita de al menos un minuto de precalentamiento hasta que entonces las salidas se desconectan Al caminar por el área de detección se conectan las salidas Cuando el movimiento cesa las salidas se mantienen conectadas durante un segundo y se desconectan 1 ...

Page 2: ... pré aquecimento até que as saídas desligam Ao caminhar pela área de detecção as saídas ligam Quando o movimento cessa as saídas mantêm se ligadas durante um segundo e depois desligam 1 AJUSTE DA TEMPORIZAÇÃO R1 e R2 O ajuste da temporização para desligar controla o tempo que as saídas de relé permanecerão ligadas após a detecção Há duas roletas giratórias de ajuste R1 e R2 com tempos de ajuste di...

Page 3: ...s connect when walking through the detection area When the movement stops the outputs keep connected during one second and then disconnect 1 TIMER ADJUSTMENTS R1 y R2 The timer adjustment to the disconnection controls the time the relay outputs will keep connected after the detection There are two adjustment spinning roulettes R1 and R2 with different adjustment times The adjustment rage of R1 is ...

Page 4: ...s se connectent Les sorties se connectent avec un déplacement dans la zone de détection Quand le mouvement cesse les sorties restent connectées pendant une seconde et ensuite se déconnectent 1 AJUSTEMENT DE LA TEMPORISATION R1 ET R2 L ajustement de la temporisation à la déconnexion contrôle la durée que les sorties de relais resteront connectées après la détection Il y a deux roulettes giratoires ...

Page 5: ...движение прекращается выходы остаются включенными в течение одной секунды после чего отключаются 1 НАСТРОЙКА ТАЙМЕРА R1 и R2 Настройка таймера отключения контролирует время в течение которого выходы реле будут оставаться включенными после детектирования Предусмотрены две вращающиеся ручки R1 и R2 с различным временем настройки Ранг настройки R1 составляет от 5 секунд до 12 минут в том время как ра...

Reviews: