Ethernet TX
Electrical specification
Data rate
Duplex
Circuit type
Transmission range
Isolation to
Connection
Shielded cable
Slot 3
12
13
14
15
16
17
18
19
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
Conductive housing
IEEE std 802.3. 2005 Edition
Slot 1 and 2: 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto
Slot 3: 10 Mbit/s, 100 Mbit/s manual or auto
Full or half, manual or auto
TNV-1
Up to 150 m with CAT5e cable or better
All other
RJ-45 auto MDI/MDI-X
Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close to
rails*
Yes
Section 2 Interface specifications
TX Ports: Slot 1 and 2: 10/100/1000 Mbit/s, Slot 3: 10/100 Mbit/s
* Note: Railway installation close to the rails. To minimise the risk of interference, a shielded cable is recommended when
the cable is located inside 3 m boundary to the rails and connected to this port. The cable shield should be properly
connected (360°) to an earthing point within 1 m from this port. This earthing point should have a low impedance
connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive
enclosure should be connected to the earthing system of an installation and may be directly connected to the
functional earth. Refer also to
Safety
section.
3BSE080639
15
Summary of Contents for NE840
Page 1: ...800xA Networks NE840 User Manual ...
Page 2: ......
Page 3: ...800xA Networks NE840 User Manual ...
Page 8: ...Licensing Information Safety 8 3BSE080639 ...
Page 33: ......