Section 2  Interface specifications 

Getting Started 

This product runs ABB Network Equipment Operating System (NEOS) which 

provides several management tools that can be used for configuration of the unit. 
NeCo - is a Network configuration management tool (NCM) made for 

commissioning and maintenance of components in a network. 
Web - Configuration of the unit using the web browser. 
CLI - Configuration of the unit via the Command Line Interface. 
If the computer is located in the same subnet as the switch you can easily use a 

web  browser to configure the unit. Within the web you can configure most of the 

available functions. 
For advanced network settings and more diagnostic information, please use the CLI.  

Detailed documentation is available in the chapter 

The Command Line  

Management Tool 

in the 

NEOS User Manual

Factory default: 

– IP address: 172.16.5.245
– Netmask: 255.255.252.0
– Gateway: Disabled

Consult your network administrator to know more on subnet. 

Configuration 

Configure the unit via Web browser. The unit can easily be configured through a 

Web browser. Open the link

 http://172.16.5.245

 in your web browser, and you will  

be prompted with a Login screen, where the default settings for Username and  

Password are: 

– Username: admin
– Password: CS4dmin

3BSE080639 

23 

Summary of Contents for NE840

Page 1: ...800xA Networks NE840 User Manual ...

Page 2: ......

Page 3: ...800xA Networks NE840 User Manual ...

Page 4: ...B ABB assumes no responsibility for any errors that may appear in this document In no event shall ABB be liable for direct indirect special incidental or consequential damages of any nature or kind arising from the use of this document nor shall ABB be liable for incidental or consequential damages arising from use of any software or hard ware described in this document This document and parts the...

Page 5: ...11 Console 12 USB 13 NetworkPorts 14 TX Ports Slot 1 and 2 10 100 1000 Mbit s Slot 3 10 100 Mbit s 15 SFP Slot 16 I O Connection 17 LED Indicators Power CPU 20 ModularTransceivers 21 Mounting 21 Rack Mounting 21 WallMounting 22 Earth Connection 22 Getting Started 23 Configuration 23 Fibre Optic Handling 24 Maintenance 24 Cleaning of the Optical Connectors 24 3BSE080639 5 ...

Page 6: ...Compliance 25 Notice FCC Part 15 105 25 Safety Control Drawing 26 AC Power Supply 27 TypeTests and Environmental Conditions 28 Referring Documents 31 Cable Factory Reset on NE840 31 Proceed with Factory Reset 31 Skip the Factory Reset 32 6 3BSE080639 ...

Page 7: ...he risk of fire use on No 26 AWG or larger telecommunication line cord Licensing Information This device contains public available software which is under the GPL license For more information see legal pdf included with all firmware releases This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit http www openssl org 3BSE080639 7 ...

Page 8: ...Licensing Information Safety 8 3BSE080639 ...

Page 9: ...e or maritime installations NE840 is designed to run efficiently from an AC power supply the unit is also equipped with configurable I O fault contact that make it ideal for easy installation and monitoring in industrial applications NE840 Model Housing NE840 is designed for installation in 19 rack solutions according to ETSI standard with a shallow depth of 240 mm as shown in Figure 1 NE840 can a...

Page 10: ...840 Specification 10 3BSE080639 Dimension W x H x D 480 x 43 x 258 mm 18 9 x 1 66 x 10 16 Weight 3 8 kg Degree of protection IP40 according to EN 60529 Cooling Convection Mounting 19 rack or wall mounted RaMa 19P 4PG 7RG Digital In Digital In Status Status ...

Page 11: ...X ports 10 100 Mbit s TX ports Power 10 100 1000 Mbit s TX ports Protective earth Section 2 Interface specifications Section 2 Interface specifications Figure 2 Interface Specifications Power Interface Specifications Figure 3 Power Interface Specifications External supply current capability for proper start up 3BSE080639 11 ...

Page 12: ...nd download the appropriate VCP driver 12 3BSE080639 External supply current capability for proper start up Power Rated Voltage 115 to 230 VAC Operating voltage 90 to 264 VAC Maximum nominal current consumption 350mA 115 VAC 60Hz 210mA 230 VAC 50 Hz Inrush current 75mA2 115 VAC 340mA2 230 VAC Rated frequency 50 60 Hz Startup current 2x nominal current Polarity Not applicable Redundant power input ...

Page 13: ... Maximum supply current 100 mA Isolation to All other except USB Galvanic connection to USB Connection USB Micro B connector in device mode USB Electrical specification USB 2 0 host interface Data rate High speed 480mbit s Circuit type SE LV Maximum supply current 500 mA Isolation to All other except console Connection USB receptacle connector type A Conductive housing Yes ...

Page 14: ...ction 2 Interface specifications 14 3BSE080639 NE840 Slot 1 1 10 100 1000 Mbit s TX port 2 10 100 1000 Mbit s TX port 3 10 100 1000 Mbit s TX port Slot 2 4 10 100 1000 Mbit s TX port 5 SFP slot 6 10 100 1000 Mbit s TX port 7 SFP slot 8 10 100 1000 Mbit s TX port 9 SFP slot 10 10 100 1000 Mbit s TX port 11 SFP slot ...

Page 15: ...Railway applications as signalling and telecommunications apparatus and located close to rails Yes Section 2 Interface specifications TX Ports Slot 1 and 2 10 100 1000 Mbit s Slot 3 10 100 Mbit s Note Railway installation close to the rails To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port The ...

Page 16: ...2 3 4 5 6 7 8 2 3 4 1 5 6 7 8 2 3 4 Slot 1 and 2 10 100 1000 Mbit s Position Direction Description 1 In Out BI_DA 2 In Out BI_DA 3 In Out BI_DB 4 In Out BI_DC 5 In Out BI_DC 6 In Out BI_DB 7 In Out BI_DD 8 In Out BI_DD Shield In Out Connected to Functional earth Direction relative this unit Section 2 Interface specifications SFP Slot Each SFP slot can hold one SFP transceiver for copper or fibre c...

Page 17: ...in series with an external voltage source is required for proper functionality For voltage current ratings see Interface specifications section The Digital in is an opto isolated digital input which can be used to monitor external events For voltage current ratings see Interface specifications section 3BSE080639 17 SFP Ports Optical Electrical specification IEEE std 802 3 2005 Edition Data rate 10...

Page 18: ...Interface specifications 18 3BSE080639 IO Relay Output Connect resistance 30 W Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Maximum voltage current 60 VDC 80 mA ...

Page 19: ...ce specifications 3BSE080639 19 IO Digital Input Voltage levels Vih 8V Vil 5V Iin 2 9mA 60V Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Maximum voltage current 60 VDC ...

Page 20: ... GREEN Power OK on DC1 RED DC1 input voltage is below operating voltage limit DC2 OFF Unit has no power GREEN Power OK on DC2 RED DC2 input voltage is below operating voltage limit AC1 OFF Unit has no power GREEN Power OK on AC1 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root...

Page 21: ...ceivers refer to Modular Transceivers User Guide 3BSE080641 The unit supports ABB transceivers only Mounting This unit can either be rack mounted or wall mounted Rack Mounting For mounting into rack use M6x25 or 1 4 x1 screws as shown in Figure 10 Figure 10 Rack Mounting 3BSE080639 21 ...

Page 22: ...ounting If mounting onto a wall as shown in Figure 11 use maximum Ø6 4 mm or 1 4 screws Figure 11 Wall Mounting Earth Connection For correct function the ground connection on the unit needs to be properly connected to a solid ground as shown in Figure 12 Figure 12 Earth Connection 22 3BSE080639 ...

Page 23: ...ser to configure the unit Within the web you can configure most of the available functions For advanced network settings and more diagnostic information please use the CLI Detailed documentation is available in the chapter The Command Line Management Tool in the NEOS User Manual Factory default IP address 172 16 5 245 Netmask 255 255 252 0 Gateway Disabled Consult your network administrator to kno...

Page 24: ...equipment needs special treatment It is very sensitive to dust and dirt If the f ibre will be disconnected from the unit the protective hood on the transmitter receiver must be connected The protective hood must be kept on during transportation The fibre optic cable must also be handle the same way If these recommendations are not followed the warranty might be jeopardized Maintenance No maintenan...

Page 25: ...truction manual may cause harmful interference to radio communications 3BSE080639 25 ABB Article Number Denomination Type Approval Compliance 3BSE080211R1 NE840 EMC EN 61000 6 1 Electromagnetic compatibility Immunity for residential environments EN 61000 6 2 Electromagnetic compatibility Immunity for industrial environments EN 61000 6 4 Electromagnetic compatibility Emission for industrial environ...

Page 26: ...3 Safety Control Drawing 26 3BSE080639 Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense RaMa 19P 4PG 7RG Digital In Digital In Status Status ...

Page 27: ... Direction relative this unit Section 2 Interface specifications AC Power Supply 3BSE080639 27 Degree of protection IP 40 Ambient temperature 40 C to 70 C ...

Page 28: ...639 Environmental phenomena Test Description Test levels ESD EN 61000 4 2 Enclosure contact 6 kV Enclosure air 8 kV RF field AM modulated IEC 61000 4 3 Enclosure 20 V m 80 AM 1 kHz 80 2700 MHz 10V m 80 AM 1 kHz 2700 6000 MHz Fast transients EN 61000 4 4 Power port 2 kV Signal ports 2 kV ...

Page 29: ... Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated emission EN 55022 Enclosure Class A FCC part 15 Enclosure Class A Conducted emission EN 55022 DC power ports Telecommunication ports Class B Class B FCC part 15 DC power ports Class B Dielectric strength EN 60950 Power port to all other ports 1 5 kVrms 50 Hz 1 min Signal ports to all other ports 1 5 kVrms 50 Hz 1 min Temperature Ope...

Page 30: ...dity Altitude Operating 2 000 m 70 kPa Service life Operating 10 years Vibration IEC 60068 2 6 Operating 7 5 mm 5 8 Hz 2 g 8 500 Hz 19 rack mounting according to IEC 60297 DIN 41494 Shock IEC 60068 2 27 Operating 15 g 11 ms 19 rack mounting according to IEC 60297 DIN 41494 Enclosure UL 94 Aluminium Zink Flammability class V 0 all models ...

Page 31: ... unit 4 Wait for the unit to start up Control that the ON LED is flashing red The ON LED flashing indicates that the unit is now ready to be reset to factory default You now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Proceed with Factory Reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables The ON LED will...

Page 32: ...reset process just wait for approximately 30 seconds after the ON LED starts flashing RED without unplugging the Ethernet cables The switch will conduct a normal boot with the existing settings Do not power off the unit while the factory reset process is in progress 32 3BSE080639 ...