LED Indicators Power/CPU
Section 2 Interface specifications
20
3BSE080639
LED
Status
Description
ON
OFF
Unit has no power
GREEN
All OK, no alarm condition
RED
Alarm condition, or until unit has started up. (Alarm
conditions are configurable, refer to
NEOS User Manual
.
BLINK
Location indicator
Here I am
. Activated when connected to
IPConfig Tool, or upon request from Web or CLI.
DC1
OFF
Unit has no power
GREEN
Power OK on DC1
RED
+DC1 input voltage is below operating voltage limit
DC2
OFF
Unit has no power
GREEN
Power OK on DC2
RED
+DC2 input voltage is below operating voltage limit
AC1
OFF
Unit has no power
GREEN
Power OK on AC1
FRNT
OFF
FRNT disabled
GREEN
FRNT OK
RED
FRNT Error
BLINK
Unit configured as FRNT Focal Point
RSTP
OFF
RSTP disabled
GREEN
RSTP enabled
BLINK
Unit elected as RSTP/STP root switch
USR1
Configurable, see
WEOS User Manual
OFF
No link
GREEN
Link established
GREEN FLASH Data traffic indication
YELLOW
Port alarm and no link. Or if FRNT or RSTP mode, port is blocked
TX/FX ports