Appendix B – Technical Data
B-2
NCAN-02 Installation and Start-up Guide
CANopen Network
Size of Network:
Max. 128 nodes
Medium:
Screened, twisted pair RS-485 cable
• Termination: 120 ohm, 1/4 W, (Metal Film)
Topology:
Multi-drop
Serial Communication Type:
Asynchronous, half Duplex
Transfer Rate:
1 Mbit/s, 500 kbit/s, 250 kbit/s, 125 kbit/s, 100 kbit/s,
50 kbit/s, 20 kbit/s, or 10 kbit/s
Protocol:
CANopen
Standards:
CAN in Automation DS 301
(Application Layer and
Communication
, DSP 402
(Device Profile: Drives and Motion Control),
ISO 11898
(Controller Area Network [CAN] for High-Speed
Communication)