2 Installation
2.1.2. Connections on the control module
3HAC021272-001 Revision: H
18
© Copyri
ght
200
4-2008 ABB.
All rights reserved.
2.1.2. Connections on the control module
Connect drive modules to the control module
xx0400001294
At delivery, both the Ethernet cable and the safety signal cable are connected to the drive
module. They are also attached to a shield plate that fits in the slot of the control module.
Remove the cover from an empty slot and fit the shield plate of the communication cables in
its place. Connect the Ethernet cable according to
Ethernet connections on page 19
and safety
signal cable according to
Safety signal connections on page 20
A
Front view of single cabinet controller
B
Back view of single cabinet controller
C
Robot communication card
D
Ethernet card (only present if more than one drive module is used)
E
Panel board
F
Slots for inserting communication cables into the control cabinet