background image

Value

Description

System option
and interface

Yes/No

This option should be selected, if the database mirroring
functions are used and this system acts as a Host. The
Host is the system that provides process data to another
system.

Database mirror-
ing HOST

For example, if you use mirroring between a communica-
tion server (front-end) and a system server, the commu-
nication server is the host.

Yes/No

This option should be selected, if the database mirroring
functions are used and this system acts as an Image. The
Image is the system that receives process data from an-
other system.

Database mirror-
ing IMAGE

For example, if you use mirroring between a communica-
tion server and a system server, the system server is the
Image.

Yes/No

This option enables the OPC DA server function. The
option should be selected, if the system is to be connected
to an external OPC DA Client e.g. 800xA, HIS 600.

OPC DA Server

0...3

This option is primarily intended for HSB systems, to which
an external OPC DA client is connected e.g. HIS 600.

Application OPC
Server

This Application OPC server is installed in the OPC DA
Client computer and provides an OPC DA server interface
that automatically connects to the Hot application of the
HSB system.

Note: There is NO A&E server interface in this option.

Yes/No

This option enables the OPC A&E server function (Alarms
& Events). The option should be selected, if the system
is to be connected to an external OPC A&E Client e.g.
800xA.

OPC A&E Server

0...4

This is a DA Client that is loosely coupled to the SYS 600
base system and can therefore be installed also in a
separate computer.

OPC DA Client
/External

It is used to connect OPC DA servers to SYS 600. You
need one client for each server that is to be connected.

Note: This DA client is used with the IEC 61850 OPC
server, but you do not have to select this option due to
the IEC 61850 communication.

0...4

The OPC DA client is used to connect foreign devices to
SYS 600 with the OPC DA interface.

OPC DA Client

You need one client for each server that is to be connec-
ted.

The DA client is tightly integrated with the process data-
base and run always on the SYS 600 computer.

33

SYS 600C 2.93

MicroSCADA Pro

Product Guide

1MRS757729

16.11.2012

Issued:

A/16.11.2012

Version:

Summary of Contents for MicroSCADA Pro SYS 600C 2.93

Page 1: ...MicroSCADA Pro SYS 600C 2 93 Product Guide ...

Page 2: ...Trace back information Workspace Main version a11 Checked in 2012 11 13 ...

Page 3: ...3 2 7 Measurement Reports Display 17 3 3 Historian 17 3 3 1 System configurations 17 3 3 2 Data logging 18 3 3 3 Visualisation 18 3 4 User management 19 3 5 Localization 19 3 6 Time synchronization 19 3 7 Redundancy 19 3 7 1 System redundancy 19 3 7 2 Communication redundancy 20 3 8 Mirroring 20 3 9 OPC connectivity 20 3 10 Cyber security 21 3 11 Key benefits 23 4 Application areas 23 4 1 Overview...

Page 4: ...0 5 2 1 Communication protocols 31 5 2 2 HSI features 32 5 2 3 System functions 34 5 3 Computer options 35 6 Hardware characteristics 35 6 1 Hardware 36 6 2 EMI EMS and environmental standard compliance 38 7 Capacity and performance 38 7 1 SYS 600C capacity 38 7 2 Data logging capacity 39 7 3 Process communication capacity 42 8 Abbreviations 4 1MRS757729 MicroSCADA Pro SYS 600C 2 93 Product Guide ...

Page 5: ...BB Oy and the contents thereof must not be imparted to a third party nor used for any unauthorized purpose The software or hardware described in this document is furnished under a license and may be used copied or disclosed only in accordance with the terms of such license Copyright 2012 ABB Oy All rights reserved Trademarks ABB is a registered trademark of ABB Group All other brand or product nam...

Page 6: ...concept discussed in the text It might indicate the presence of a hazard which could result in corruption of software or damage to equipment property Information icon alerts the reader to relevant factors and conditions Tip icon indicates advice on for example how to design your project or how to use a certain function Although warning hazards are related to personal injury and caution hazards are...

Page 7: ...00 9 3 System Configuration 1MRS757728 SYS 600C User s Guide 2 4 Document revisions History Date Product Version Revision Document created 16 11 2012 2 93 A 7 SYS 600C 2 93 MicroSCADA Pro Product Guide 1MRS757729 16 11 2012 Issued A 16 11 2012 Version ...

Page 8: ...presented on the HSI or forwarded to other systems See Section 3 9 OPC connectivity for more connectivity options 3 1 1 Remote communication The remote communication is used to connect SYS 600C to upper level systems such as Network Control Systems The most common protocols such as IEC 60870 5 101 104 DNP 3 0 and MODBUS are supported See Section 5 2 1 Communication protocols for the full list of s...

Page 9: ...ns of the workplaces can be fully customized for each user The distributed workplace concept is based on available remote access techniques typically Remote Desktop Services Any PC or other web enabled device can be used as a workstation without installing any additional software 3 2 2 Process Display One of the display types of the workplace is the process display The process display is used to r...

Page 10: ...on about the base system applications redundancy communication lines IEDs and so on The system can also receive status information from any device or external software reporting to the Windows event log for example disks power supplies and computer boards Communication equipment and peripheral devices that support SNMP can also be supervised by using a third party product SNMP OPC gateway 10 1MRS7...

Page 11: ...make the right decisions and verify that taken measures have been successfully performed You can also receive information about activities carried out by other users operations of objects acknowledging of alarms editing of limit values logging in and all other type of events which can occur 11 SYS 600C 2 93 MicroSCADA Pro Product Guide 1MRS757729 16 11 2012 Issued A 16 11 2012 Version ...

Page 12: ...Display The Alarm Display shows a summary of the present alarm situation of the supervised process Each alarm is normally presented as an alarm text row which describes the cause of the alarm in the process With default settings the alarm text row normally has a time stamp an object identification an object text and text indicating the alarm status See Figure3 4 for Alarm Display Template 1 and Fi...

Page 13: ...ters Alarm Display setting tool for colors and text layout Updating Frozen modes Alarm acknowledgement Alarm reset function Authorization support Help in all dialogs The complete manual will be opened from Help Visible Alarm Class Locate object in DMS Locate object in Monitor Pro 13 SYS 600C 2 93 MicroSCADA Pro Product Guide 1MRS757729 16 11 2012 Issued A 16 11 2012 Version ...

Page 14: ...play main view Figure 3 6 The Blocking Display main view The Blocking Display contains of the following features and options Selection of signal s for blocking deblocking Blocking Display setting tool for the view layout Printout of blocking situation Event and printout enabling disabling Authorization support Possibility to copy contents on the clipboard of the operating system Help in all dialog...

Page 15: ...ds Display The Trends Display contains the following features Graphical or tabular view Zooming mode Scrolling with scroll bars and panning Configurable axes and line properties Using legend Using hairline Update interval options from 10 seconds to 10 minutes Calculation formulas direct mean sum integral and difference Clearing trend data by the user Save Open and Delete preconfigurations Printout...

Page 16: ...e reports Hourly report time resolution 1 2 3 5 6 10 15 20 or 30 minutes Daily report time resolution 10 15 30 or 60 minutes Weekly report time resolution 1 day Monthly report time resolution 1 day Yearly report time resolution 1 month Quick Report on an hourly basis time resolution according to a period cycle Quick report on a daily basis time resolution according to a period cycle Quick report o...

Page 17: ...s commonly known tools for further data refinement 3 3 1 System configurations Historian should primarily be used on a dedicated server The data sources for Historian are Process Objects or Data Objects of SYS 600C The data is transfer from SYS 600C to the Historian over a TCP IP LAN One SYS 600C application can log data into one or several Historian instances and one Historian instance can receiv...

Page 18: ...Visualisation of the logged and refined data is done by means of various graphs and tables The graphs can be freely configured in terms of graphical representation axes types and orientation update rates etc The numerical tables are utilising Microsoft Excel and provides flexible configuration and data manipulation possibilities Figure 3 10 An example of Historian graphs 3 4 User management Users ...

Page 19: ...stem can be further improved by redundant servers configured in a hot stand by mode HSB In this configuration one computer is active and receives and processes all data from the process It also manages the displays and provides data for the displays At the same time all process data and configuration data is shadowed over to the stand by computer The stand by computer is in the same state as the a...

Page 20: ...as event buffering during communication breaks and handling of hot stand by configurations are automatically taken care of The data mirroring takes place between a host and an image The host is the source for the process data and the image is a copy of the process data The SYS 600C node that receives the process data for example through IEC 61850 or LON is the host This process data can be mirrore...

Page 21: ...servers Support for redundant remote communication lines Support for redundant power supplies for both AC and DC power supply Engineering efficiency Integrated tools for system engineering for example expansion of databases communication system HSI clients and users Support for third party software and hardware through the use of open interface and communication Easy to upgrade with latest softwar...

Page 22: ...e line diagrams process displays trends reports control alarms and events Process displays with support for zoom pan de clutter Trends with zoom pan multiple graph types ruler cut and paste 22 1MRS757729 MicroSCADA Pro SYS 600C 2 93 Product Guide ...

Page 23: ...t use of known technologies and intuitive user interfaces ensures an easy entry level for new SYS 600C users 4 1 1 Fields of application SYS 600C is designed to be used in a wide range of applications in both Electrical Utilities and Industries When using SYS 600C in substations the main application is as a Communication Gateway to the upper level system or it is used as a powerful Control System ...

Page 24: ...he SYS 600C Communication Gateway function can be configured as a single gateway as shown in Figure 4 1 Figure 4 1 SYS 600C as Communication Gateway Utilizing the OPC interface in SYS 600C enables an easy and efficient integration of IED signals and information into a DCS system as shown in Figure 4 2 This configuration is typically applied in Process Industries with distributed Intelligent Electr...

Page 25: ... SYS 600C as Control System HSI SYS 600C HSI provides numerous options for monitoring and controlling a connected process SYS 600C handles both the HSI functionality and the Communication Gateway functionality In this way SYS 600C can act both as a Communication Gateway enabling a remote connection to control centers as well as the local control system and HSI user interface on a station level The...

Page 26: ...ystem HSI and Communication Gateway For increased availability SYS 600C can be configured as a redundant Control System HSI and integrated Communication Gateway with redundant communication lines to Remote Control Center as shown in Figure 4 7 Figure 4 7 SYS 600C as redundant Control System HSI and integrated Communication Gateway SYS 600C can also be utilized as an HSI for station RTU as shown in...

Page 27: ...rge number of serial communication ports and LAN ports in combination with the solid state technology offers an excellent Communication Server solution The Communication Server solution is offered and available as a part of larger SYS 600 or SYS 600C configurations as shown in Figure 4 9 and Figure 4 10 Figure 4 9 SYS 600C as Communication Server in a Remote Control Center system 27 SYS 600C 2 93 ...

Page 28: ...0C Communication Server solution the processing load in the main system servers SYS 600 or SYS 600C is reduced The Communication Servers are connected to the process devices and provide the main system servers SYS 600 or SYS 600C with process information 28 1MRS757729 MicroSCADA Pro SYS 600C 2 93 Product Guide ...

Page 29: ...be purchased from external suppliers 5 1 2 Operating systems The operating system can be upgraded after the delivery The operating system upgrades are not delivered from the ABB product unit but can be purchased from an external supplier The operating system must be compatible with both the computer and the SYS 600 software Operating system security updates and service packs are tested and verifie...

Page 30: ...aster protocols Master protocol IEC 61850 8 1 Client LON LAG SPA Bus IEC 60870 5 101 IEC 60870 5 103 IEC 60870 5 104 Single or redundant DNP 3 0 LAN WAN DNP 3 0 Serial Modbus RTU Modbus TCP IP RP 570 571 ANSI X3 28 FD HD P214 ADLP 180 IEC 61107 metering Alpha Meter protocol RCOM Table 5 2 Slave protocols Slave protocol IEC 60870 5 101 Single or redundant IEC 60870 5 104 Single or redundant DNP 3 0...

Page 31: ... option if you want to use dynamic network coloring in the Process Displays Network coloring Yes No Select this option if you want to use the Trend displays in the Workplaces Trends Yes No Select this option if you want to use the Event List dis plays in the Workplaces Event list Yes No Select this option if you want to use the Alarm List dis plays in the Workplaces Alarm list Yes No Select this o...

Page 32: ...xim um 14 000 indica tions and 14 000 commands con figured within SYS 600C Table 5 5 System options and interfaces Value Description System option and interface Yes No This option enables control commands to be issued from the system Control This option should normally be selected This option can be left out in pure monitoring systems where no output process objects are needed You also need this o...

Page 33: ...Application OPC Server This Application OPC server is installed in the OPC DA Client computer and provides an OPC DA server interface that automatically connects to the Hot application of the HSB system Note There is NO A E server interface in this option Yes No This option enables the OPC A E server function Alarms Events The option should be selected if the system is to be connected to an extern...

Page 34: ... the system server will write in all databases together Historian tags 0 20 This option specify the number of workplaces totally in all Historian systems the system server will write data to Historian worksta tions 5 3 Computer options The SYS 600C computer options are presented in the following tables Table 5 6 Hardware Hardware Power Supply 88 132 VAC 45 160 VDC Single or redundant Power Supply ...

Page 35: ...J45 2 x USB at rear panel USB 2 0 1 x USB at front panel 1 x USB internal AC97 2 1 Audio PS 2 Keyboard Mouse SYS 600C uses the optical industrial grade SFP connector module FTM 8012C SLiG from Source Photonics Fiberxon LC module data Module details Data rate 1250Mb s wavelength 850nm multimode temperature range 40 C 85 C 40 F 185 F 88 132 VAC 45 160 VDC Power supply 176 264 VAC 200 370 VDC AC Powe...

Page 36: ... 2004 Level 4 4KV line to earth 2KV line to line Surge Immunity IEC 61000 4 5 2005 Level 3 10Vrms Conducted RF Immunity IEC 61000 4 6 2006 Level 5 100A m 5min 1000A m 1s Magnetic Field Immunity IEC 61000 4 8 2001 Level 4 30A m Damped Magnetic Immunity IEC 61000 4 10 1993 Level 3 2 5KV common Differen tial 1 25KV for Substation Damped Oscillatory Burst IEC 61000 4 12 1995 Level 3 15Hz 150KHz Conduc...

Page 37: ...erature Range IEEE C37 90 Table 6 4 Environmental standard compliance Severity level Description Type test 30 C Start Up for 16 hours Cold Temperature IEC 60068 2 1 65 C Start Up for 16 hours Dry Heat Temperature IEC 60068 2 2 Test Db 6 cycles 25 C 55 C 93 95 1 cycle 24hrs Humidity Damp heat Cyclic IEC 60068 2 30 95 non condensing 40 C 2d Humidity Damp heat Steady state IEC 60068 2 3 10 200 500 20...

Page 38: ...rkplaces they consume computer capacity and thereby the process communication capacity must be reduced accordingly For IEC 61850 the capacity is mainly affecting the number of messages and thus it is more important that this is reduced than the number of IEDs The impact on the process communication capacity of the other functions is given in percentage Example How many IEDs can be connected over I...

Page 39: ...ing tables show the maximum communication capacity for the most commonly used protocols Table 7 1 Maximum communication capacity Comments Value IEC 61850 1920 s Nr of messages 160 Nr of IEDs 4 Nr of IEC 61850 clients LON Maximum 30 IEDs per XLON card 90 Nr of IEDs Limited by available PCI slots 3 Nr of XLON cards IEC 103 200 Nr of IEDs Limited mostly by maximum response time 15 Nr of IEDs line IEC...

Page 40: ...asure ment objects in Workplace 2 when Process display with 150 switching device objects in Workplace Per Workplace with Trends with 10 curves on 30 seconds interval logging 1 Trends Workplace with data logging Per Workplace with Measurement Reports with 15 min report 1 Reports Workpace with data logging Total of 900 objects data logged by Measure ment Reports The following list shows some example...

Page 41: ...hows some examples when IEDs are connected to SYS 600C with Local process database and displayed with Workplaces 60 IEDs with IEC 61850 protocol and 1 Workplace with 1 050 display objects 63 IEDs with IEC 61850 protocol and 2 Workplaces both including 450 display objects 77 IEDs with IEC 61850 protocol and 1 Workplace including 150 display objects 41 SYS 600C 2 93 MicroSCADA Pro Product Guide 1MRS...

Page 42: ...ea Network LAN Light Emitting Diode LED Mean Time Between Failure MTBF Network Control Center NCC OLE for Process Control OPC Programmable Logic Controller PLC Remote Terminal unit RTU Simple Network Management Protocol SNMP Simple Network Time Protocol SNTP Solid State Drive SSD Product name SYS 600 Product name SYS 600C Universal Serial Bus USB Video Graphics Array VGA Virtual Private Network VP...

Page 43: ......

Page 44: ... us 1MRS757729 A 16 11 2012 Copyright 2012 ABB All rights reserved ABB Oy Substation Automation Products P O Box 699 FI 65101 Vaasa FINLAND Tel 358 10 22 11 Fax 358 10 224 1094 www abb com substationautomation ...

Reviews: