Quick installation guide - MicroFlex e190
8
Wire sizes and tightening torques:
X1A: Dinkle EC762V-B3253206P-BK
X1B: Dinkle EC762V-B3253203P-BK
0.2...6.0 mm
2
(30*...10 AWG)
* Minimum size for UL installations is 14 AWG.
Torque: 0.7 N·m (6.2 lbf·in)
X2: Phoenix Contact MVSTBR 2,5HC/ 2-ST-5,08
0.2...2.5 mm
2
(24...12 AWG)
Torque: 0.6 N·m (5.3 lbf·in)
X3, X4: Weidmüller B2L 3.50/20/180,
Weidmüller B2L 3.50/8/180
0.2...1.0 mm
2
(28...16 AWG)
Notes:
The wiring shown is for demonstrative purposes only.
Complete information for all connectors, including X7
and X8, is provided in
MicroFlex e190 User’s Manual
(code: 3AXD500000373236).
E1/E2
Ethernet fieldbus
IN
E2
OUT
E1
X1A
115...240 V AC ±10%
input
L1
1
L2
2
L3
3
DC bus-
UDC-
4
Brake resistor
R-
5
DC bus+ / Brake res.
R+/UDC+
6
X1B
Motor output
U
1
V
2
W
3
E3
Ethernet host (PC)
1
X3
X3
1
Status-/DO0-
Status-/DO0+
11
2
DO2-
DO2+
12
3
DO1-
DO1+
13
4
DI2-
DI2+
14
5
DI3-
DI3+
15
6
DI1-
DI1+
16
7
DI0-
DI0+
17
8
AGND
AO0
18
9
AI0-
AI0+
19
10
Shield
Shield
20
E2
Connectors
E1
X1A
X1B
E3
X3
X4
X8
X7
X2
SW2
Universal encoder input
supports multiple
feedback types.
See
MicroFlex e190
User’s Manual.
X4
X4
1
STO1
STO1
11
2
STO2
STO2
12
3
SGND
SGND
13
4
24 V out
24 V out
14
Safe Torque Off: Both circuits must be closed for the drive to start.
All connections are duplicated for easy wiring.
X2
(Optional) External
power input: 24 V, 1 A
0 V
1
+24 V IN
2
M
Example:
STO input
using internal
24 V supply
Example:
STO input
using external
24 V supply
Safe Torque Off
Input/ Output
Ethernet fieldbus
Incremental encoder
in/out
X8 voltage selector
Optional 24 V supply
Ethernet host (PC)
E190QuickStartGuide.book Page 8 Thursday, May 18, 2017 10:40 AM