Note
Action
Both the protection and the strap
are included in the spare part no.,
specified in
xx0500002320
Fit a cable protection to the lower arm, if not
already mounted, with two securing screws (A),
M6x16.
Secure the cable harness with two velcro straps
(B), with a distance of approximately 180 mm. Fix
the strap by wrapping it two turns around the
largest cable before wrapping around the com-
plete harness.
18
Shown in the figure
.
Refit the cable harness to the
guide plate axis 2
.
19
Shown in the figure
.
Refit the
velcro strap
at the guide plate axis 2.
20
Detailed in the Calibration chapter
- section
If the connection between the SMB battery and
the SMB unit has been broken, the revolution
counters must now be updated!
21
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in the section
22
240
Product manual - IRB 6650S
3HAC020993-001 Revision: Z
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.3.2 Replacement of cable harness, axes 1-4
Continued