![ABB IRB 6650S - 200/3.0 Product Manual Download Page 239](http://html1.mh-extra.com/html/abb/irb-6650s-200-3-0/irb-6650s-200-3-0_product-manual_3640954239.webp)
4 Repair
4.3.6. Replacement of air nipple and hose (Foundry Prime)
237
3HAC020993-001 Revision: G
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
Required equipment
Procedure
The following procedures details how to replace the Foundry Prime air nipples and hose. The
pos. no. in following procedures correspond to the illustration in
Required equipment on page 237
1E
200
1F
35
1G
250
1H
730
1K
4290
1L
195
1M
40
1N
40
1P
1605
1Q
100
1R
1490
1S
570
Pos
Length in mm.
Equipment
Art. no.
Pos. in illustration
Velcro strap
3HAC12625-1
9
Cable straps
21662055-3
8
Elbow fitting
40
6
Rubber clamp
3HAC026523-001
5
T-plug connector
3HAC026515-001
4
Y-plug connector
3HAC026514-001
3
Bulkhead plug connector
3HAC026513-001
2
Hose
3HAC026526-001
1
Action
Note/Illustration
<<
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot.
Localise the damaged hose or air
connector, and Continue to replace the
damaged hose route the hose according to
the following illustrations
Continued
Continues on next page