2 Installation and commissioning
2.4.5. Installation of position switches (option)
3HAC020993-001 Revision: G
92
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
2.4.5. Installation of position switches (option)
General
Position switches can be installed on axes 1-3. The position switches include cams as shown
in the figures below.
The position switch kits may be delivered in one of two ways:
•
Fitted by ABB Robotics on delivery. In this case, the cams must still be fitted and
locked by the user. For axis 1, the cover for the cams must also be fitted.
•
As kits to be completely fitted to the robot and adjusted by the user.
Required equipment
Description
Art. no.
Note
Position switch, axis 1
3HAC 15715-1
Includes position swtich and plate for
customer connections.
Position switch, axis 2
3HAC 021884-001
Includes only the position switch.
Position switch, axis 3
3HAC 16417-2
Includes only the position switch.
Cabling, position switches and
cooling fans, axes 1, 2 and 3
3HAC 16659-1
Cabling to be installed on the robot.
Plate for customer connections
3HAC 025778-001
An additional connection plate must
be fitted to the robot base, if not
already installed. The plate is shown
in the figure
.
Additional cabling to and inside
the controller
-
Specified in section
and connection points on page 101
Connector kit R1.SW1
3HAC 17252-1
Connector kit R1.SW2/3
3HAC 17253-1
Continues on next page