Operation Manual / TPS44-F.. - TPS61-F..
Removal and installation
7
Remove the turbocharger
7.3
Page 87
© Copyright 2016 ABB. All rights reserved.
A
ug
us
t2
01
7
H
ZT
L2
41
2_
E
N
R
ev
is
io
n
F
Remove the turbocharger
7.3
τ
Disconnect all exhaust gas and air lines according to the instructions
of the enginebuilder.
Version with water-cooled bearing casing:
τ
Disconnect the water pipes according to the instructions of the en-
ginebuilder.
If present, remove hard insulation as follows:
τ
Remove screws and sheet metal (B) from the bearing casing insula-
tion.
τ
Remove the remaining screws from the bearing casing insulation (A).
τ
Pull the bearing casing insulation up and off. The bearing casing insu-
lation can be compressed to facilitate the removal process.
τ
Unplug the cable connector from the speed sensor.
τ
Attach lifting gear to bearing casing.
τ
If a gas outlet bend is present, sling lifting gear around it or secure it to
the lifting gear with a swivel lifting eye (C).
τ
Loosen the fixing screws (D) on the bearing casing.
τ
Lift the turbocharger from the engine and put it down.
τ
Cover oil connections.
7.3