Operation Manual / TPL76-C
Maintenance
5
Cleaning the compressor during
operation
5.3
Page 60
© Copyright 2016 ABB. All rights reserved.
D
ec
em
ber
2016
H
ZT
L2485_
EN
R
ev
is
ion
D
Wet cleaning using external water-pressure vessel (XC3)
Operating state prerequisites for compressor cleaning with XC3
NOTICE
In order to carry out a successful cleaning procedure that has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisite must be met:
Engine load 50 – 85%
Start cleaning cycle according to following description Wet cleaning
operation with XC3.
Operating procedure for compressor wet cleaning with XC3
The operating state prerequisites for compressor cleaning with XC3
must be fulfilled.
Remove sealing plug (X).
Fill vessel with required volume of clean water (see table Cleaning pa-
rameters).
5.3.2
Operating the water