I N S T A L L A T I O N P R O C E D U R E S
80
FOX615
Installation
UR
Upper Rail in the subrack
LR
Lower Rail in the subrack
LC
Latching clips (not available on all units!)
To remove units from the subrack you have to reverse the steps required for
the installation of units. Proceed as follows:
Unit removal
Proceed as follows:
1. Remove the front cover from the subrack.
−
Refer to
Figure 53: Removing the front cover from the subrack
page 83) and proceed as instructed in the corresponding paragraphs.
2. Remove the cable clamp(s) from the subrack earthing bar(s).
−
Refer to
Figure 47: Cable clamps and earthing bars (conductive foam
in bars and clamps is dark shaded)
(on page 73) and proceed as
instructed in the corresponding paragraphs for the left and/or the right
side cable clamps.
3. Unplug the connector(s) of the signal cable
−
Check for latching clips (refer to positions (LC) in
) or other
strain relieve devices.
−
Separate at the same time both clips (or other devices) from their
notch in the cover of the connector.
−
Unplug the connector now.
4. Remove the unit (
−
Unscrew both fixing screws (14) of the unit.
−
To disengage the unit from the backplane connectors push both levers
(11) and (12) simultaneously in outward position (A). Allow the unit to
move outside while pressing on the levers.
−
Remove (B) the unit from the subrack.
−
Handle the unit according to the recommendations for ESD sensitive
devices.
5. Repeat the steps 3 to 4 for all units to remove.
End of instruction