I N S T A L L A T I O N P R O C E D U R E S
FOX615
Installation
67
• Wire diameter: typ. 0.8 mm (AWG 20)
• Wire insulation diameter: 1.3 … 3.1 mm
For each connection you have to crimp a Mini-Fit HCS
TM
crimp terminal on
the corresponding cable. The crimp terminal is then inserted with the cable fit
into the Molex connector frame in the appropriate position.
A connector set with connector frames (1 frame 4x2, 1 frame 3x2) and crimp
terminals (14 Mini-Fit HCS
TM
) is available for optional alarm signal connec-
tions.
For details of the crimp process, refer to the instructions provided with the
crimp tool (for the crimp tool reference, refer to
3.7.3.2
Alarm signal input interfaces
The FAMO1 or FAMO1-F
provides 3 interfaces for the monitoring of alarm
signals (inputs) for totally 12 alarm signals. Each interface can handle up to
4 alarm signals.
Figure 39: FAMO1 and FAMO1-F
alarm signals input interfaces
Each alarm interface F3, F4, F5 uses a pin assignment as follows:
Figure 40: Molex connector frame alarm signal inputs
Standard crimp contacts are connected and implemented within the individ-
ual Molex connector frames as required for monitored alarm signals.
If the DUPF1 is implemented it uses 2 of the 12 alarm inputs. For details,
refer to section
F3 : Alarm inputs
1 -4
F4: Alarm inputs
5-8
F5: Alarm inputs
9-12
F2: Alarm output
1-2
50
moving fans
refer to handbook
F3 F4 F5
fan 48 VDC 19" 1U
37970003
R2A
2111743473
2011 W44
1
2
3
4
5
6
7
8
Table 6:
Alarm input interfaces pin connection
Alarm Interface
Connector Pin
F3
F4
F5
Signal
GND
Alarm_in 1
Alarm_in 5
Alarm_in 9
8
4
Alarm_in 2
Alarm_in 6
Alarm_in 10
7
3
Alarm_in 3
Alarm_in 7
Alarm_in 11
6
2
Alarm_in 4
Alarm_in 8
Alarm_in 12
5
1